User manual
...the world's most energy friendly microcontrollers
2012-04-24 - Giant Gecko Family - d0053_Rev0.96 700
www.energymicro.com
28.5.9 ADCn_IFC - Interrupt Flag Clear Register
Offset Bit Position
0x020
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
Access
W1
W1
W1
W1
Name
SCANOF
SINGLEOF
SCAN
SINGLE
Bit Name Reset Access Description
31:10 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
9 SCANOF 0 W1 Scan Result Overflow Interrupt Flag Clear
Write to 1 to clear scan result overflow interrupt flag.
8 SINGLEOF 0 W1 Single Result Overflow Interrupt Flag Clear
Write to 1 to clear single result overflow interrupt flag.
7:2 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
1 SCAN 0 W1 Scan Conversion Complete Interrupt Flag Clear
Write to 1 to clear scan conversion complete interrupt flag.
0 SINGLE 0 W1 Single Conversion Complete Interrupt Flag Clear
Write to 1 to clear single conversion complete interrupt flag.
28.5.10 ADCn_SINGLEDATA - Single Conversion Result Data
Offset Bit Position
0x024
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x00000000
Access
R
Name
DATA
Bit Name Reset Access Description
31:0 DATA 0x00000000 R Single Conversion Result Data
The register holds the results from the last single conversion. Reading this field clears the SINGLEDV bit in the ADCn_STATUS