User manual

...the world's most energy friendly microcontrollers
2012-04-24 - Giant Gecko Family - d0053_Rev0.96 640
www.energymicro.com
Bit Name Reset Access Description
Set bit X to enable channel X
25.5.8 LESENSE_SCANRES - Scan result register (Async Reg)
For more information about Asynchronous Registers please see Section 5.3 (p. 20) .
Offset Bit Position
0x01C
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0000
Access
R
Name
SCANRES
Bit Name Reset Access Description
31:16 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
15:0 SCANRES 0x0000 R Scan results
Bit X will be set depending on channel X evaluation
25.5.9 LESENSE_STATUS - Status Register (Async Reg)
For more information about Asynchronous Registers please see Section 5.3 (p. 20) .
Offset Bit Position
0x020
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
0
0
Access
R
R
R
R
R
R
Name
DACACTIVE
SCANACTIVE
RUNNING
BUFFULL
BUFHALFFULL
BUFDATAV
Bit Name Reset Access Description
31:6 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
5 DACACTIVE 0 R LESENSE DAC interface is active
4 SCANACTIVE 0 R LESENSE is currently interfacing sensors.
3 RUNNING 0 R LESENSE is active
2 BUFFULL 0 R Result buffer full
Set when the result buffer is full
1 BUFHALFFULL 0 R Result buffer half full
Set when the result buffer is half full