User manual
...the world's most energy friendly microcontrollers
2012-04-24 - Giant Gecko Family - d0053_Rev0.96 597
www.energymicro.com
Bit Name Reset Access Description
7:0 REP1 0x00 RW Repeat Counter 1
Optional repeat counter or buffer for REP0
23.5.9 LETIMERn_IF - Interrupt Flag Register
Offset Bit Position
0x020
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
0
Access
R
R
R
R
R
Name
REP1
REP0
UF
COMP1
COMP0
Bit Name Reset Access Description
31:5 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
4 REP1 0 R Repeat Counter 1 Interrupt Flag
Set when repeat counter 1 reaches zero.
3 REP0 0 R Repeat Counter 0 Interrupt Flag
Set when repeat counter 0 reaches zero or when the REP1 interrupt flag is loaded into the REP0 interrupt flag.
2 UF 0 R Underflow Interrupt Flag
Set on LETIMER underflow.
1 COMP1 0 R Compare Match 1 Interrupt Flag
Set when LETIMER reaches the value of COMP1
0 COMP0 0 R Compare Match 0 Interrupt Flag
Set when LETIMER reaches the value of COMP0
23.5.10 LETIMERn_IFS - Interrupt Flag Set Register
Offset Bit Position
0x024
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
0
Access
W1
W1
W1
W1
W1
Name
REP1
REP0
UF
COMP1
COMP0
Bit Name Reset Access Description
31:5 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
4 REP1 0 W1 Set Repeat Counter 1 Interrupt Flag
Write to 1 to set the REP1 interrupt flag.
3 REP0 0 W1 Set Repeat Counter 0 Interrupt Flag
Write to 1 to set the REP0 interrupt flag.
2 UF 0 W1 Set Underflow Interrupt Flag
Write to 1 to set the UF interrupt flag.