User manual

...the world's most energy friendly microcontrollers
2012-04-24 - Giant Gecko Family - d0053_Rev0.96 595
www.energymicro.com
23.5.4 LETIMERn_CNT - Counter Value Register
Offset Bit Position
0x00C
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0000
Access
RWH
Name
CNT
Bit Name Reset Access Description
31:16 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
15:0 CNT 0x0000 RWH Counter Value
Use to read the current value of the LETIMER.
23.5.5 LETIMERn_COMP0 - Compare Value Register 0 (Async Reg)
For more information about Asynchronous Registers please see Section 5.3 (p. 20) .
Offset Bit Position
0x010
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0000
Access
RW
Name
COMP0
Bit Name Reset Access Description
31:16 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
15:0 COMP0 0x0000 RW Compare Value 0
Compare and optionally top value for LETIMER
23.5.6 LETIMERn_COMP1 - Compare Value Register 1 (Async Reg)
For more information about Asynchronous Registers please see Section 5.3 (p. 20) .