Bit Name Reset Access Description
When set, the voltage regulator is enabled in EM4, enabling operation of the Backup RTC and retention registers.
10.5.6 EMU_BUCTRL - Backup Power configuration register
Offset Bit Position
0x030
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0
0
0
0
Access
RW
RW
RW
RW
Name
PROBE
BODCAL
STATEN
EN
Bit Name Reset Access Description
31:7 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
6:5 PROBE 0x0 RW Voltage probe select
Configure which voltage to export to ADC
Value Mode Description
0 DISABLE Disable voltage probe
1 VDDDREG Connect probe to VDD_DREG
2 BUIN Connect probe to BU_IN
3 BUOUT Connect probe to BU_OUT
4:3 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
2 BODCAL 0 RW Enable BOD calibration mode
When set, the Backup BOD sensing on VDD_DREG will be sensing the DAC output.
1 STATEN 0 RW Enable backup mode status export.
When enabled, BU_STAT will indicate when backup mode is active.
0 EN 0 RW Enable backup mode
Backup mode will be entered when main power browns out and backup battery is present.
10.5.7 EMU_PWRCONF - Power connection configuration register.
Offset Bit Position
0x034
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0
0
0
0
Access
RW
RW
RW
RW
Name
PWRRES
VOUTSTRONG
VOUTMED
VOUTWEAK
Bit Name Reset Access Description
31:5 Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
4:3 PWRRES 0x0 RW Power domain resistor select
Select value of series resistor between main power domain and backup power domain.
Value Mode Description
0 RES0 Main power and backup power connected with RES0 series resistance.