User's Guide

BAT-X
5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620
P: +1 (949) 748-8895
E: info@mobilogix.com
© MOBILOGIX, INC.
5 OPERATING MODES
5.1 NORMAL MODE
Normal Mode will allow BAT-X to go between sleeping and active work states to report data to the cloud. Active work states
are triggered by hold-off timers and threshold values according to the BAT-X configuration.
Entry Triggers:
Factory Mode to Normal Mode: Charge for 10 minutes
Discovery Mode to Normal Mode: Write operation via Bluetooth
Exit Triggers:
Normal Mode to Discovery Mode: REST API
Normal Mode to Factory Mode: FOTA
Available Functions:
Normal Reporting:
o Login
o Location Data
o Sensor Data
o Beacon Report
Alarm Reporting:
o Lux
o Movement
o Impact/Drop
Configuration
FOTA
Radio Modes:
Cellular (BG96): Follows configured settings for wake/sleep
Bluetooth (BG13): Scanning for beacons