5 OPERATING MODES
5.1 NORMAL MODE
Normal Mode will allow BAT-X to go between sleeping and active work states to report data to the cloud. Active work states
are triggered by hold-off timers and threshold values according to the BAT-X configuration.
Entry Triggers:
• Factory Mode to Normal Mode: Charge for 10 minutes
• Discovery Mode to Normal Mode: Write operation via Bluetooth
Exit Triggers:
• Normal Mode to Discovery Mode: REST API
• Normal Mode to Factory Mode: FOTA
Available Functions:
• Normal Reporting:
o Login
o Location Data
o Sensor Data
o Beacon Report
• Alarm Reporting:
o Lux
o Movement
o Impact/Drop
• Configuration
• FOTA
Radio Modes:
• Cellular (BG96): Follows configured settings for wake/sleep
• Bluetooth (BG13): Scanning for beacons