User's Guide

BAT-X
5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620
P: +1 (949) 748-8895
E: info@mobilogix.com
© MOBILOGIX, INC.
2 INTRODUCTION
This document describes the Mobilogix BAT-X (Basic Asset Tracker, ATD500X). BAT-X is an asset tracker equipped with LTE
CatM1/NB1, quad-band 2G, Bluetooth, GNSS, environmental, and IMU sensors. The BAT-X may be in one of three operating modes.
Factory mode is set on BAT-X during production for initial delivery and long-term storage of BAT-X. In Factory mode no radios are on,
BAT-X waits for 10 minutes of charging to switch to Normal Mode. While in Normal mode, BAT-X will collect the asset location and
sensor data and report the data to a cloud platform via cellular air interface. During Normal mode BAT-X may also collect peripheral
data via Bluetooth beacon scanning. After a report BAT-X will sleep until the next report (based on configured hold-off timers and
thresholds). While not tracking any assets, or for short term storage, Discovery mode may be entered. Discovery mode shuts down
all radios except Bluetooth until a wake-up command is received to push BAT-X into Normal mode.
3 FIRMWARE
3.1 FIRMWARE VERSIONS
BAT (Dam App): V5.0.2-official
BG96 (Cellular): BG96MAR02A10M1G
BGM13P (Bluetooth): V502A3
4 QUICK START
4.1 HOW TO TURN BAT-X ON
From the factory BAT-X must be connected to charger for 10 minutes to enter Normal Mode. Once BAT enters Discovery Mode
it will send BT advertisements a unique name based on the cellular IMEI. To Switch BAT-X from Discovery Mode to Normal Mode
write 1 to the Cycling Power Vector.
4.2 LED STATUS INDICATORS
Data LED
Slow, short blinks:
Trying to register
Slow, long blinks:
Registered but idle
Fast blinks:
Data in transit
Power LED
Green:
100% - 40%
Yellow:
39% - 20%
Red:
19% - 0%
GNSS LED
Blinking:
Acquiring location
Solid:
Location acquired