Specifications

AN93
20 Rev. 0.9
2.3.2. Analog Output
Figure 8 illustrates an optional application circuit to support the analog output capability of the Si2493/57/34/15/04
for call progress monitoring.
Figure 8. Optional Connection to AOUT for a Monitoring Speaker
Table 8. Component Values—Optional Connection to AOUT
Symbol Value
C2, C3, C5 0.1 µF, 16 V, ±20%
C4 100 µF, 16 V, Elec. ±20%
C6 820 pF, 16 V, ±20%
R1 10 kΩ, 1/10 W, ±5%
R2 10 Ω, 1/10 W, ±5%
R3 47 kΩ, 1/10 W, ±5%
U1 LM386
AOUT
C5
R2
C4
Speaker
+5 V
3
2
6
4
+
+
5
C2 R3
C3
R1
C6
U1