Specifications

Si2404
6 Rev. 0.91
Table 4. AC Characteristics
(V
D
= 3.0 to 3.6 V, TA = 0 to 70 °C for K-Grade, Fs = 8 kHz)
Parameter Symbol Test Condition Min Typ Max Unit
Sample Rate Fs 8 kHz
Clock Input Frequency F
XTL
default 4.9152 MHz
Clock Input Frequency
F
XTL
>10 k resistor between pin 23
and GND
—27—MHz
Receive Frequency Response Low –3 dBFS Corner, FILT = 0 5 Hz
Receive Frequency Response Low –3 dBFS Corner, FILT = 1 200 Hz
Transmit Full Scale Level
1
V
FS
—1.1—V
PEAK
Receive Full Scale Level
1,2
V
FS
—1.1—V
PEAK
Dynamic Range
3
DR ILIM = 0, DCV = 11, MINI = 00
DCR = 0, I
L
= 100 mA
—80— dB
Dynamic Range
3
DR ILIM = 0, DCV = 00, MINI = 11
DCR = 0, I
L
=20mA
—80— dB
Dynamic Range
3
DR ILIM = 1, DCV = 11, MINI = 00
DCR = 0, I
L
=50mA
—80— dB
Transmit Total Harmonic
Distortion
4
THD ILIM = 0, DCV = 11, MINI = 00
DCR = 0, I
L
= 100 mA
—–72— dB
Transmit Total Harmonic
Distortion
4
THD ILIM = 0, DCV = 00, MINI = 11
DCR = 0, I
L
=20mA
—–78— dB
Receive Total Harmonic
Distortion
4
THD ILIM = 0, DCV = 00, MINI = 11
DCR = 0, I
L
=20mA
—–78— dB
Receive Total Harmonic
Distortion
4
THD ILIM = 1,DCV = 11, MINI=00
DCR = 0, I
L
=50mA
—–78— dB
Dynamic Range (Caller ID Mode) DR
CID
VIN = 1 kHz, –13 dBm 50 dB
Notes:
1. Measured at TIP and RING with 600 termination at 1 kHz, as shown in Figure 1 on page 5.
2. Receive full scale level produces –0.9 dBFS at DTX.
3. DR = 20 x log |Vin| + 20 x log (rms signal/rms noise). Applies to both transmit and receive paths. Vin = 1 kHz, –3 dBFS.
4. Vin = 1 kHz, –3 dBFS. THD = 20 x log (rms distortion/rms signal).