2.1 I/O Ports
Each I/O port can be configured as an input or output. When configured as input, each I/O port, except pins
P1_0 and P1_1, can also be configured with internal pull-up, pull-down or tri-state. Pull-down or pull-up can
only be configured to whole port, not individual pins. Unused I/O pins should have defined level and not be
floating. See the Profile Toolkit developer guide for more information about the configuration.
During reset the I/O pins are configured as inputs with pull-ups. P1_0 and P1_1 are inputs but do not have
pull-up or pull-down.
2.2 UART
UART baud rate can be configured up 2 Mbps. See the Profile Toolkit developer guide for more information.
Following table lists commonly used baud rates for BLE113
Baud rate (bps)
Error (%)
2400
0.14
4800
0.14
9600
0.14
14 400
0.03
19 200
0.14
28 800
0.03
38 400
0.14
57 600
0.03
76 800
0.14
115 200
0.03
230 400
0.03