User's Manual

Table Of Contents
SPI Slave Timing
Table 4.27. SPI Slave Timing
Parameter Symbol Test Condition Min Typ Max Unit
SCKL period
1, 2
t
SCLK_sl
2 *
t
HFPERCLK
ns
SCLK high period
1, 2
t
SCLK_hi
3 *
t
HFPERCLK
ns
SCLK low period
1, 2
t
SCLK_lo
3 *
t
HFPERCLK
ns
CS active to MISO
1, 2
t
CS_ACT_MI
4 50 ns
CS disable to MISO
1, 2
t
CS_DIS_MI
4 50 ns
MOSI setup time
1, 2
t
SU_MO
4 ns
MOSI hold time
1, 2
t
H_MO
3 + 2 *
t
HFPERCLK
ns
SCLK to MISO
1, 2
t
SCLK_MI
16 +
t
HFPERCLK
66 + 2 *
t
HFPERCLK
ns
Note:
1.
Applies for both CLKPHA = 0 and CLKPHA = 1 (figure only shows CLKPHA = 0)
2.
Measurement done with 8 pF output loading at 10% and 90% of V
DD
(figure shows 50% of V
DD
)
CS
SCLK
CLKPOL = 0
MOSI
MISO
t
CS_ACT_MI
t
SCLK_HI
t
SCLK
t
SU_MO
t
H_MO
t
SCLK
_MI
t
CS_DIS_MI
t
SCLK_LO
SCLK
CLKPOL = 1
Figure 4.2. SPI Slave Timing Diagram
BGM113 Blue Gecko Bluetooth
®
Smart Module
Data Sheet
Electrical Specifications
silabs.com | Smart. Connected. Energy-friendly. Preliminary Rev. 0.93 | 35