User's Manual

Table Of Contents
4.1.3.4 Current Consumption Using Radio
Table 4.6. Current Consumption Using Radio 3.3 V with DC-DC
Parameter Symbol Test Condition Min Typ Max Unit
Current consumption in re-
ceive mode, active packet
reception (MCU in EM1 @
38.4 MHz, peripheral clocks
disabled)
I
RX
1 Mbit/s, 2GFSK, F = 2.4 GHz,
Radio clock prescaled by 4
8.7 mA
Current consumption in
transmit mode (MCU in EM1
@ 38.4 MHz, peripheral
clocks disabled)
I
TX
CW, 0 dBm, F = 2.4 GHz, Radio
clock prescaled by 3
8.8 mA
CW, 3 dBm, F = 2.4 GHz 17.6 mA
RFSENSE current consump-
tion
I
RFSENSE
51 nA
4.1.4 Wake up times
Table 4.7. Wake up times
Parameter Symbol Test Condition Min Typ Max Unit
Wake up from EM2 Deep
Sleep
t
EM2_WU
Code execution from flash 10.7 μs
Code execution from RAM 3 μs
Wakeup time from EM1
Sleep
t
EM1_WU
Executing from flash 3 AHB
Clocks
Executing from RAM 3 AHB
Clocks
Wake up from EM3 Stop t
EM3_WU
Executing from flash 10.7 μs
Executing from RAM 3 μs
Wake up from EM4H Hiber-
nate
1
t
EM4H_WU
Executing from flash 60 μs
Wake up from EM4S Shut-
off
1
t
EM4S_WU
290 μs
Note:
1.
Time from wakeup request until first instruction is executed. Wakeup results in device reset.
BGM113 Blue Gecko Bluetooth
®
Smart Module Data Sheet
Electrical Specifications
silabs.com | Smart. Connected. Energy-friendly. Preliminary Rev. 0.93 | 16