Data Sheet
Bluegiga Technologies Oy
Page 39 of 52
7 Electrical Characteristics
7.1 Absolute Maximum Ratings
Parameter
Min
Max
Unit
V
in
-0.3
7.0
V
Voltage on ordinary I/O
-0.3
3.63
V
3V3 current drain*
200
mA
Permissible ambient temperature
(Commercial version)
0
70
°C
Permissible ambient temperature
(Industrial version)
-40
85
°C
Storage temperature
-40
85
°C
Table 50: Absolute Maximum ratings
*Pins 9, 10, 11, 12 are 3.3V outputs intended for 3.3V low power devices.
Stresses beyond those listed in Table 50 may cause permanent damage to the device.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Table 50 gives stress ratings only—functional operation of the device is not implied beyond the
conditions indicated in Table 51.
7.2 Recommended Operating Conditions
Parameter
Min
Max
Unit
V
in
4.75
5.25
V
Voltage on ordinary I/O
3.1
3.4
V
Board temperature (Industrial version)
-40
85
°C
Ambient temperature with high Wi-Fi use
(Industrial version)
-40
60
°C
Table 51: Recommended Operating Conditions