Note: Once the daemon rebuilds to a designated Hot Spare, a designated Hot Spare will not exist
and the SteelVine processor will rebuild to empty space.
With Automatic Rebuild and Immediate Rebuild options selected, the daemon automatically
initiates an immediate rebuild. If the end-user wants the daemon to delay the rebuild until after the
first write to the SAFE volume, select the Rebuild Only If Needed option. The latter setup allows
temporary removal of a hard disk drive without requiring a rebuild. To minimize the possibility of data
loss, the rebuild process should be set up to start immediately.
With Manual Rebuild selected, the end-user decides when to initiate rebuild following a rebuild
prompt. Unless the SiI 4726 Manager is actively monitored, the Automatic rebuild should be set
up to minimize the possibility of data loss.
Note: In case the end-user selects No in response to a rebuild prompt, select Scan Devices from the
File menu of the Status window to trigger a new prompt.
If a power failure interrupts a rebuild, the daemon will restart the rebuild process.
Configure a rebuild
1. Select Specify Policy from the Edit menu of the Status window.