User guide

ezRAID3 Manager GUI Version 1.0
7 Rebuild & Schedule Drive Verify
This chapter describes the procedures for the following procedures:
x Manually start or abort a Rebuild operation
x Manually start or abort a Verify operation
x Schedule or modify an automatic Rebuild operation
Note: This set of features is only enabled when at least one SAFE volume exists.
Start Rebuild
If the hard drive should fail in any way, the SteelVine Manager is set up by default to
automatically begin the rebuild process. Once the Rebuild and Verify operation has been
completed, the disk will be available for optimal use.
When a SAFE volume exists (including the SAFE component of a SAFE33 or a SAFE50
Storage Policy), you can request a drive rebuild if the disk was marked bad or a previous
rebuild operation was aborted. To start the rebuild, select
Action Æ Start Rebuild Æ Select
Drive n
. Once a rebuild process has been started, it can also be aborted.
Once the rebuild has taken place, the Verify process will begin automatically if your system
is configured to do so. If the rebuild process is ever interrupted, the rebuild process will
resume from the last 10 GB segment that was completed before the interruption occurred.
ezRAID3 RAID Manager User's Guide
Page 56