User guide
ezRAID3 Manager GUI Version 1.0
6 View Policy Settings
Overview
The Policy Settings dialog allows you to view the current settings for Rebuild and Verify
operations for SAFE volumes, including:
Init Rebuild: Defines whether to automatically copy (mirror) the contents of Disk 0 to
Disk 1 whenever a new SAFE volume configuration is created. When this policy is
“Enabled”, the data from Disk 0 will be automatically copied (mirrored) to Disk 1.
When this policy is “
Disabled”, no automatic copy is performed.
Auto Rebuild: Defines whether to remember the non-usable state of a hard drive if it is
disconnected and then re-connected to the SteelVine Storage Processor. When this
policy is “
Enabled”, the system will always attempt to rebuild a disk that has been
inserted, even if that disk had previously been identified as non-usable. When this
policy is “
Disabled”, the system will not rebuild a disk that had previously been
identified as non-usable.
Verify Rebuild: Defines whether to automatically perform a verification of the data after
a rebuild operation is completed. When this policy is set to “
Enabled”, a verification
of the copied data is automatically performed. When this policy is “
Disabled”, an
automatic verification of the copied data is not performed, and any verification would
need to be launched manually through the SteelVine Manager GUI.
These settings are based on the hard-strapping of GPI pins 5, 6 and 8 and cannot be modified
through the SteelVine Manager GUI.
Accessing the Policy Settings Dialog
Use the following procedure to open the Policy Settings Dialog.
1. Click on the Policy Settings icon along the top of the SteelVine Manager Status window.
Note: This selection is only available when at least one SAFE volume exists.
View Policy Settings icon
ezRAID3 RAID Manager User's Guide
Page 54