User`s guide
Document Number: MAN-002000-000 Version 2.6
Sil 4726 Manager User’s Guide
Page 57
The ‘StatusScreenTitleBar’ is where the end-user can change the Name seen at the top of the GUI. To edit this
feature, change the XML tag text string that says ‘SiI 4726 Manager’.
<StatusScreenTitleBar>
SiI 4726 Manager</StatusScreenTitleBar>
<StatusScreenTitleBar>
Your Company Name</StatusScreenTitleBar>
The ‘AllowPolicyChages’ – True – turns on the Policy feature. If the end-user changes the XML tag value to
False, the Policy Icon will not appear in the GUI and the feature will not be available.
<AllowPolicyChanges>True</AllowPolicyChanges>
<AllowPolicyChanges>False</AllowPolicyChanges>
The ‘AllowAdvancedConfig’ – True – turns on the Advanced Config feature. If the end-user changes the XML
tag value to False, the general Configure feature will still be available, but the Advanced button (inside the
Configuration feature) will not be available.
<AllowAdvancedConfig>True</AllowAdvancedConfig>
<AllowAdvancedConfig>False</AllowAdvancedConfig>
Note: If the file is missing from the working directory, the GUI will allow both policy changes and
advanced mode, as well as the status screen title to be set to “Sil4726”. If there are any errors in
the XML tag value, the Advanced Configuration button will not be available in the Configuration
Setup.
If there is an error in the XML tag value, a pop-up window will appear notifying the end-user of the error and
the tag where it can be found.