User`s guide

A Look at the SiI 4726 Status Window
9
The Status window displays a separate tab for each SiI 4726 Storage Appliance attached to the host
computer.
Table 1 Sections of the Status Window
Status Cells Description
System Status section
Temp Indicates the current temperature of the Sil 4726 Storage Appliance.
Fan Speed Indicates the system fan status. Use this data to monitor possible malfunctions.
Drive Status section
Box Status
Shows the drive status: Normal, Rebuilding, Unplugged, Needs Rebuild, New
Drive, Wrong Slot.
Drive S/N Shows the unique serial number assigned by the disk manufacturer.
Exp. S/N
Shows the expected serial number of the hard disk drive. The daemon compares
the Expected and actual Drive serial numbers to detect when a drive's status
changes.
Capacity Information section
Policy Shows the storage policy configured for each vollume.
Total Shows the combined capacity of the volume.
Drive # Shows capacity information for each hard disk drive.
Capacity Shows the full amount of storage space (in GB) available on each hard disk drive.
Volume
Shows the total volume capacity and the drive capacities assigned to each
volume.