Install Manual

Document Number: MAN-SSI-02 | SAFETY AND INSTALLATION MANUAL FOR PHOTOVOLTAIC MODULES
6
MOUNTING FOR SIL HN
Allowed positions for fixing
the SIL HN module using
mounting clamps.
Mounting must stay WITHIN
the coloured areas.
*Positive values correspond to downward forces, Negative Values correspond to uplift forces
ATTENTION:
In the case of installation with
modules in the portrait configura-
tion, install the modules with the
junction boxes at the top in their
“upright” position. This will reduce
the risk of moisture ingress into the
junction box.
206.5
331.5
431.5
431.5
331.5
206.5
1400
1600
1850
MOUNTING TYPE MOUNTING POSITION MOUNTING ZONE DESIGN LOAD RATING* TEST LOAD RATING
Clamp /
Mounting Holes
Long Edge
Primary
331.5mm-431.5mm +3600Pa/ -1600Pa +5400Pa/ -2400Pa
Clamp
Long Edge
Secondary
206.5mm-331.5mm +1600Pa /-1600Pa +2400Pa /-2400Pa
SIL HN
=
=
Long Edge Primary Mounting Zone