Install Manual
5
Document Number: MAN-SSI-02 | SAFETY AND INSTALLATION MANUAL FOR PHOTOVOLTAIC MODULES
MOUNTING FOR SIL HC
Allowed positions for fixing
the SIL HC module using
mounting clamps.
Mounting must stay WITHIN
the coloured areas.
*Positive values correspond to downward forces, Negative Values correspond to uplift forces
ATTENTION:
In the case of installation with
modules in the portrait configura-
tion, install the modules with the
junction boxes at the top in their
“upright” position. This will reduce
the risk of moisture ingress into the
junction box.
200
200
131
256
356
356
256
131
250
250
1050
1250
1500
MOUNTING TYPE MOUNTING POSITION MOUNTING ZONE DESIGN LOAD RATING* TEST LOAD RATING
Clamp /
Mounting Holes
Long Edge
Primary
256mm-356mm +3600Pa/ -3600Pa +5400Pa/ -5400Pa
Clamp
Long Edge
Secondary
131mm-256mm +2667Pa /-1600Pa +4000Pa /-2400Pa
Clamp Short Edge 200mm-250mm +1600Pa/ -1600Pa +2400Pa/ -2400Pa
=
=
Long Edge Primary Mounting Zone
Long Edge Secondary Mounting Zone
SIL HC
Short Edge Mounting Zone
=