4
MOUNTING FOR SIL BK
Allowed positions for fixing
the SIL BK module using
mounting clamps.
Mounting must stay WITHIN
the coloured areas.
*Positive values correspond to downward forces, Negative Values correspond to uplift forces
ATTENTION:
In the case of installation with
modules in the portrait configura-
tion, install the modules with the
junction boxes at the top in their
“upright” position. This will reduce
the risk of moisture ingress into the
junction box.
950
1150
1400
01234567891W
422.5
197.5
322.5
422.5
322.5
197.5
170
170
220
220
=
=
Long Edge Primary Mounting Zone
Long Edge Secondary Mounting Zone
MOUNTING TYPE MOUNTING POSITION MOUNTING ZONE DESIGN LOAD RATING* TEST LOAD RATING
Clamp /
Mounting Holes
Long Edge
Primary
322.5mm-422.5mm +3600Pa/ -2667Pa +5400Pa/ -4000Pa
Clamp
Long Edge
Secondary
197.5mm-322.5mm +2667Pa /-1600Pa +4000Pa /-2400Pa
Clamp Short Edge 170mm-220mm +1600Pa /-1470Pa +2400Pa /-2200Pa
SIL BK
Short Edge Mounting Zone
=