6
Fig. 4a: cross section
of a mounting clamp
to be used for at-
taching the modules
to support structure
(minimum length is
40 mm).
Fig. 4d: end of module
row with additional
spacer (item 05: 50mm x
30mm x 24mm)
Fig. 4c: modules at-
tached to supporting
structure – side view
Fig. 4b: modules attached
to supporting structure
(rail, item 01) using a clamp
(item 02) xed with a bolt
(item 03) and nut (item
04) – view between two
modules.
1 Rail 2 Clamp 3 Bolt 4 Nut
A
DETAIL A
Bonding Pins
(Module Frame Bonding)
Bonding Bolt
(Rail Bonding)
Fig. 4e: CAMO hidden
end clamp. Clamp
slide into rail channel
and the bonding pins
contacts the module
ange edge.