Install Manual

Document Number: MAN-SFO-15 | SAFETY AND INSTALLATION MANUAL FOR PHOTOVOLTAIC MODULES
4
RECOMMENDED
A photovoltaic system composed of Silfab modules
mounted on a UL2703 certied mounting system
should be evaluated in combination with roof cover-
ings in accordance with UL 1703 standard meet the
requirements to achieve the specied System Fire
Type designation for a non-BIPIV module or panel.
For instance, if a listed mounting system with Class
A System rating is installed with type 1 modules,
the photovoltaic system is suitable to maintain the
System Class A Fire Rating.
Any mounting system limitations on inclination
or accessories required to maintain a specied
System Fire Class Rating should be clearly spec-
ied in the installation instruction and UL2703
certication of the mounting system supplier.
Recommended clearance distance of 115mm
(4.5inch) (recommended) between module frame
and the surface of the wall or roof. Other
mounting techniques may aect the UL Listing
or the re class ratings.
200
425
850
200
60
7x12 (x4)
Mounting Hole
Drainage (x8)
Ø4.2 (x2)
Grounding Hole
1200±10
1700±0.5
1000±0.5
38
1700±0.5
Back View
Side View
200
496
1000
60
7x12 (x4)
Mounting Hole
Drainage (x8)
Ø4.2 (x2)
Grounding Hole
1200±10
200
994±0.5
1992±0.5
38
Grounding Hole
1992±0.5
Back View
Side View
Fig. 3a: Mechanical drawing
of the SIL NL, SIL ML, SIL HL
and SIL XL modules showing
the mounting holes, the
drainage holes, and the ground
connection holes.
Fig. 3b: Mechanical drawing of
the SIL NT and SIL MT modules
showing the mounting holes, the
drainage holes, and the ground
connection holes.