Install Manual
Document Number: MAN-SFO-15 | SAFETY AND INSTALLATION MANUAL FOR PHOTOVOLTAIC MODULES
4
RECOMMENDED
A photovoltaic system composed of Silfab modules
mounted on a UL2703 certied mounting system
should be evaluated in combination with roof cover-
ings in accordance with UL 1703 standard meet the
requirements to achieve the specied System Fire
Type designation for a non-BIPIV module or panel.
For instance, if a listed mounting system with Class
A System rating is installed with type 1 modules,
the photovoltaic system is suitable to maintain the
System Class A Fire Rating.
Any mounting system limitations on inclination
or accessories required to maintain a specied
System Fire Class Rating should be clearly spec-
ied in the installation instruction and UL2703
certication of the mounting system supplier.
Recommended clearance distance of 115mm
(4.5inch) (recommended) between module frame
and the surface of the wall or roof. Other
mounting techniques may aect the UL Listing
or the re class ratings.
200
425
850
200
60
7x12 (x4)
Mounting Hole
Drainage (x8)
Ø4.2 (x2)
Grounding Hole
1200±10
1700±0.5
1000±0.5
38
1700±0.5
Back View
Side View
200
496
1000
60
7x12 (x4)
Mounting Hole
Drainage (x8)
Ø4.2 (x2)
Grounding Hole
1200±10
200
994±0.5
1992±0.5
38
Grounding Hole
1992±0.5
Back View
Side View
Fig. 3a: Mechanical drawing
of the SIL NL, SIL ML, SIL HL
and SIL XL modules showing
the mounting holes, the
drainage holes, and the ground
connection holes.
Fig. 3b: Mechanical drawing of
the SIL NT and SIL MT modules
showing the mounting holes, the
drainage holes, and the ground
connection holes.