Datasheet
Port Commands
Table 36 Port Commands
Command Description
SH PORT Shows port parameters
Sample output:
Port Q-Size Type Attributes
*S1 0 serial 115200 N 8 1 XON/XOFF
CLEAR PORT S1 JOB Aborts the active job on the port.
If the remote host is connected, additional data received will be discarded.
Format:
CL PORT S1 JOB
SET PORT S1 FLOW Sets serial port flow control to NONE, XON/XOFF, CTS, or DSR
The default value is none.
Format:
SET PORT S1 FLOW <flow>
SET PORT S1
PARITY
Sets serial port parity to NONE, EVEN, ODD, MARK, or SPACE
The default value is none.
Format:
SET PORT S1 Parity <parity>
SET PORT S1 SIZE Sets data bits on the serial port
The default value is 8.
Format:
SET PORT S1 SIZE [7 | 8]
SET PORT S1 Speed Sets serial port baud rate. Options for BAUD are 300, 600, 1200, 2400, 7200, 9600,
19200, 38400, 57600, 115200, 230400, 460800, 921600
The default value is 115200.
Format:
SET PORT S1 SPEED <baudrate>
SET PORT S1 STOP Sets serial port stop bits per character
The default value is 1.
Format:
SET PORT S1 STOP [1 | 2]
Part Number 40183-101 Silex SX-550 Developer's Guide Page 89