Datasheet

Command Description
Local> set gpio trig 1 1
Local> set gpio trig 0 2
Local> show gpio trig
GPIO Trigger Conditions
-----------------------
trig if GPIO #1 is 1 <Trig #1>
trig if GPIO #2 is 0 <Trig #2>
GPIO #2 is set for OUTPUT
GPIO #3 is set for OUTPUT
SET GPIO TRIGM <bit-mask>
Sets all trigger control bits. <bit-mask> is a 32-bit
mask expressed in hex digits. The mask is encoded
as follows:
31 30 29 28 27 26 25 24
N/A N/A N/A N/A N/A N/A N/A N/A
23 22 21 20 19 18 17 16
TRIG16 TRIG15 TRIG14 TRIG13 TRIG12 TRIG11 TRIG10 TRIG9
GPIO10 GPIO9 GPIO6 GPIO5 GPIO4 GPIO3 GPIO2 GPIO1
1 to 0 1 to 0 1 to 0 1 to 0 1 to 0 1 to 0 1 to 0 1 to 0
15 14 13 12 11 10 9 8
N/A N/A N/A N/A N/A N/A N/A N/A
7 6 5 4 3 2 1 0
TRIG8 TRIG7 TRIG6 TRIG5 TRIG4 TRIG3 TRIG2 TRIG1
GPIO10 GPIO9 GPIO6 GPIO5 GPIO4 GPIO3 GPIO2 GPIO1
0 to 1 0 to 1 0 to 1 0 to 1 0 to 1 0 to 1 0 to 1 0 to 1
A value of 1 enables the corresponding GPIO trigger
condition. A value of 0 disables the corresponding
trigger condition. For example, a hex value of 4
enables a GPIO3 0 to 1 transition as a trigger.
NOTE: Setting the trigger mask resets all undefined
trigger strings for triggers that are enabled to the
default trigger string value.
NOTE: The trigger configuration is not changed by a
configuration reset to default.
SHOW GPIO TRIGM Shows all trigger control bits.
Part Number 40183-101 Silex SX-550 Developer's Guide Page 61