Network Card User's Manual

silex Page 33
Part Number 40183-101
Chapter 6:
Setting Configuration Parameters
The SX-550 module is equipped with a default configuration that works with most serial-to-Ethernet and
wireless connections. You can modify the settings to suit your installation requirements.
ExtendView is the recommended method for setting configuration parameters. However, regardless of the
method to access the configuration parameters, the method for modifying the parameters is virtually
identical.
Factory Default Settings
Table 19 displays the configuration parameter descriptions and settings with the default settings indicated
in a separate column.
Table 19 Factory Default Settings
Parameter Description Settings Default Setting
Character Bits per character 7, 8 8
Flow Flow control None, Xon, Xoff,
CTS/RTS
None
Parity Parity None, Even, Odd, Mark,
Space
None
Speed Baud rate of bits per second 300, 600,1200, 2400,
3600, 4800, 7200,
9600, 14400,19200,
38400, 57600, 76800,
115200, 230400,
460800, 921600
9600
115200 – console
port default
Stop Stop bits per character 1, 2 1
Mode Line mode or serial port protocol 232, 422, 485, 485HD,
Disabled
232
Ecable E-cable mode for TCP connections Enable, Disable Disable
Ecaddr E-cable destination IP address Set by user N/A
Econn E-cable connection attempt time 1-255 seconds 30 seconds