User`s guide

SX-500 User’s Guide
Page
7
Factory Default Settings
The Serial Server is shipped with a default configuration that will work with the most common serial-to-Ethernet and
wireless connections. The default settings can be changed to suit specific installation requirements via the
ExtendView Utility, the embedded Web server, or via a Telnet connection to the Serial Server’s internal console. The
factory default settings can be easily restored at any time by performing a cold reset (press and hold the pushbutton
on the device for more than five seconds).
Port Parameters
Parameter Description Settings
CHARACTER bits per character 7, 8 (default)
FLOW flow control NONE (default), Xon/Xoff, CTS/RTS
PARITY parity NONE (default), EVEN, ODD, MARK, or SPACE
SPEED baud rate (bits per second) 300, 600, 1200, 2400, 3600, 4800, 7200, 9600
(default), 14400, 19200, 38400, 57600, 76800,
115200 (console port default), 230400, 460800
STOP stop bits per character 1 (default), 2
MODE line mode (serial port protocol) 232 (default), 422, 485, 485HD, Disabled
ECABLE E-Cable mode (for TCP connections) Enable, Disable (default)
ECADDR E-Cable destination IP address (set by user)
ECONN E-Cable connection attempt time 20 seconds
ECPORT E-Cable destination IP port number 9100 (default), or set by user