Product specifications
Advanced Configuration
Silex
Page 35
Part Number 140-00188-180
Table 9 Extended AT Commands
Parameter
Command
Description
Console pass through
AT#C<string>
Passes the string to the server configuration console.
The string can be any valid console command. Refer
to your server documentation for console commands
available on your unit.
Since this command does not follow the normal AT
command format of <command><number>, it must
be the last command on the line unless the next
command is a '#' command. All characters up to the
end of line or a '# will be considered part of the
console command.
If console quiet mode is not is enabled, then the
response will be the standard console task response.
Example:
AT#Cset nw ssid silex#Csave
Console Quiet mode
AT#Qn
If n = 0, a response to a #C command is given.
If n = 1, the response is not provided. The default
after reset is 1.