Installation manual
Only use or build mounting/support systems that can handle the load of the gener -
ator and the blast pressure of the wind in any condition.
Working on the mounting system should only be carried out on a calm day. Make
sure that nobody is close to the mast.
Disconnect the battery from the charge controller when working in the
system. The turning of the blades must be avoided by fixing one blade to the
mast. If not the charge controller will be destroyed.
Only persons with appropriate technical skills and knowledge should carry out the
electrical installation. Before a storm the SILENTWIND should be manually
stopped with the stop switch on the charge controller. In case of storms we recom -
mend fixing one rotorblade to the mast due to the risk of damage by flying objects.
2.3. Installation risks
3.1. Wind generator
3. Technical data
7
3.1.1 Electrical data
Type of generator
Rated voltage
Rated power
Rated peak power at
Start up speed
Start of charging
Permanent magnet generator, 3 phases, AC
12 VDC / 24 VDC / 48 VDC
420 Watt / 450 Watt / 500 Watt
14.5 m/s
2 m/s
2.2 m/s