Installation manual
Make sure that you install the wind generator in a position where nobody can touch
the blades. On boats, always ensure it is mounted a sufficient height above the
deck.
The blades are produced from carbon fibre, which is extremely hard and therefore
potentially dangerous at high wind speeds. Always keep clear of the turning blades
in all circumstances. However, Blades can break due to ropes or other objects
touching them in very strong winds.
If one of the blades is damaged, immediately activate the BRAKE function using
the stop switch on the charge controller. If one of the blades is damaged, the rotor
system will be out of balance which may be a risk for the whole mounting construc -
tion. This has to be considered before mounting the wind generator in a safe
position.
Before you install the wind generator on a mast make sure that the 3-phase wiring
is disconnected from the charge controller and the three wires shorted together.
This has the same effect as the BRAKE switch on the controller but should be the
method used during installation. If possible, it is best to attach the hub with the
blades to the shaft at the very end of the mounting procedure. The mast must be
well secured so that it is safe in strong winds and adverse sea conditions. Addition -
ally, the mast and the mast stays should be assembled in such a way that vibra -
tions will be not magnified. Please ask a professional who is able to assess the load
that the mounting system can handle in strong wind conditions.
6
A running wind generator can generate a considerable AC voltage and current per
phase. Only connect the components if you are familiar with electric wiring. The
high voltage can cause serious injury and fire if you do not pay attention to safety.
Caution is recommended for people with cardiac pacemakers, etc. Never touch
the open end of the wires. The current when charging the batteries can reach more
than 30A. The whole wiring and connection points must be able to carry a current
of 40A. Information about suitable cable size is on page 9.
Warning: Wires with inadequate diameter can cause fire.
Make sure all wires are placed so that mechanical damage cannot occur. A
damaged cable is a severe safety risk. Install a fuse between the charge controller
and the battery positive pole; as close as possible to the battery. The required
value of the fuse depends on the rated current of the wind generator and solar
panels connected to the charge controller. Please contact a professional for this
purpose. We recommend a fuse with the double nominal current of the connect -
ed devices.
Warning: When connecting charge controller to the battery, sparks can occur.
A short circuit is to be avoided.
Always ensure sufficient ventilation!
2.2. Electrical risks