Specifications
Programming
151018 5-25
5.4.4.2 How to Select the Receiver Mode
In large central stations where calls may be coming in on several receivers at once, one of the
receivers can be selected as the master unit and all others can be selected as slave units in
order to route the flow of data.The Master Slave relationship between receivers can operate in
two ways, Master Printer/Slave Printer, and Master Automation/Slave Automation. A Master
Printer can not be paired with a Slave Automation and vise versa. Master Printer will output
data to the printer connected to it when the automation system fails. The Master Automation
receiver will pass all data from slave receivers to the automation system.
1. Enter program mode. (See Section 5.1.)
2. Press for general options.
3. Press for system options.
4. Press or until the Receiver Mode programming field is flashing.
5. Press the or button until desired setting is flashing.
6. Press .
5.4.4.3 How to Set the Receiver ID Number
1. In large central stations where calls may be coming in on several receivers at once, the
automation software will need to identify which receiver it received a call from. This will
help in troubleshooting if a problem occurred with the automation system or receiver.
2. Enter program mode. (See Section 5.1.)
3. Press for General Options.
4. Press for System Options.
5. Press until the Receiver ID programming field is flashing Rcvr ID=01.
6. The display will flash on the receiver ID number: Rcvr ID=01
7. Enter the desired receiver ID number (a number from 01 to 99).
8. Press .