Instructions / Assembly
APPLICATION INSTRUCTIONS
SUBSTRATE QUALITY
Mortar and concrete must be at the required strength.
No need to be 28 days old.
▪
Substrate strength (concrete, masonry, natural stone)
must be verified.
▪
Pull-out tests must be carried out if the substrate
strength is unknown.
▪
The anchor hole must always be clean, dry, free from
oil and grease etc.
▪
Loose particles must be removed from the holes.▪
Threaded rods and rebars have to be cleaned
thoroughly from any oil, grease or any other
substances and particles such as dirt etc.
▪
MIXING
Getting the cartridge ready
1. Unscrew the cap
2. Cut the film
3. Screw on the static
mixer
4. Place the cartridge into
the gun and start
applicatio
Product Data Sheet
Sika AnchorFix® S
June 2018, Version 01.02
020205010010000003
5 /