TDS
TECHNICAL INFORMATION
Tensile Adhesion Strength
The above values represent mean ultimate values and allowable working loads. The allowable working loads
have been reduced using a safety factor of 4.0 for tension and 3.0 for shear, however, in some cases, such as
life safety, safety factors of 10.0 or higher may be necessary.
1.
Allowable loads must be checked against steel capacity. The lowest value controls.2.
Tabulated data is applicable to single anchors in normal weight concrete unaffected by edge or spacing
reduction factors. Values are valid for anchors installed into dry concrete in holes drilled with a hammer drill
and ANSI carbide drill bit.
3.
Service temperatures should remain approximately constant. The maximum long term temperature being
122 °F and the maximum short term temperature being 176 °F. Short term temperatures are those that
occur over brief intervals, for example, diurnal cycling.
4.
Linear interpolation is allowed.5.
*The design professional on the job is ultimately responsible for the interpretation of the data provided above.
Service Temperature
Long term 40 °F (4 °C) min. / 122 °F (50
°C) max.
Short term (1–2 hours) 176 °F (80 °C)
(ETAG 001, Part 5)
Allowable Tension, N
all
= 0.33 x f
u
x nominal cross sectional area
Allowable Shear, V
all
= 0.17 x f
u
x nominal cross section area
*The design professional on the job is ultimately responsible for the interpretation of the data provided above.
Design Considerations
Product Data Sheet
Sika® AnchorFix-2
February 2020, Version 01.04
020205010020000001
2 /
8