User`s manual

RAID
2-15
2-8 Rebuilding a Failed Mirrored set
The steps below will guide you in rebuilding a failed Mirror set.
When a failure to one member occurs you will be notified either by
the RAID BIOS Utility during boot or by the Medley GUI while in
Windows. In either event enter the RAID BIOS utility, dissolve the
current RAID set, replace the failed drive, then re-configure the
mirror with the good drive as the source drive and the new drive
as the destination drive.
1. During boot press F3 to enter the RAID BIOS Utility.
2. Press F1 to dissolve an Array.
3. Press the number of the Mirrored array to be dissolved.
4. Press Y to confirm be sure you delete the correct Array.
5. Press ESC to exit the RAID BIOS utility,then immediatly turn
off the computer.
6. Replace the bad drive with a new hard drive of equal or
greater size.
7. During boot press F3 to enter the RAID BIOS Utility.
8. Press F2 to Create an Array.
9. Press F2 to create a Mirrored Array.
10. Answer N for Automatic setup.
11. Enter the number of the SOURCE (good)drive.
12. Enter the number of the DESTINATION (new) drive.
13. Answer Y to copy from the Source to the Destination drive.
14. Answer N to decline Offline Copy.
15. Answer Y to enable Auto-rebuild.
16. When asked Are You Sure?, Press Y to accept.
17. Press ESC to exit the RAID BIOS utility and reboot the
computer.
Note: Ignore the error message displayed by the RAID BIOS
and continue booting. The mirror will rebuild automatically.