User`s manual
RAID
2-9
2. Choose F3 and the following screen appears:
Select the chunk size to be used in RAID 0 set:
A=Auto Configure 0=1k 1=2k 2=4k 3=8k 4=16k 5=32k 6=64k
7=128k 8=256k 9=.5M
Your selection?
3. Select A to Auto Configure(recommended) or choose a desired
chunk size to manually configure. If choosing manual
configuration the following screen appears:
Enter the first source drive number in Mirrored-Striped set:
Note: The TOTAL size of a Mirrored-Striped set is the
combined size of the two source drives.
4. To optimize throughput, have both source drives be from
different channels and then both destinations drives be from
different channels. It also must be remembered that the total
capacity of the source drives must be LESS THAN OR
EQUAL TO the total capacity of the destination drives (for
example, choose 0). The following screen appears:
Enter the second source drive number in Mirrored-Striped
set:
5. For example, choose 2. The following screen appears:
Enter the first destination drive number in Mirrored-Striped
set:
6. For example, choose 1. The following screen appears:
Enter the second destination drive number in Mirrored-
Striped set:
7. For example, choose 3. The following screen appears:
Are you sure? (Y/N)
8. Enter Y to create Mirrored-Striped set. The following screen
appears:
Drive Number: 0 Manufacturer Model 19541 MB
Drive Number: 1 Manufacturer Model 19541 MB
Secondary Channel:
Drive Number: 2 Manufacturer Model 19541 MB
Drive Number: 3 Manufacturer Model 19541 MB
Set: 1 <0,2><1,3> CMD Mirrored-Striped<PM>39081 MB