2
Power Requirement: 0.2A @ +5V
Operating Temperature: 32° to 122° (0° to 50°C)
Storage Temperature: -40° to 158°F (-40° to 70°C)
Relative Humidity: 5% to 90%, non-condensing
Dimensions: 122mm (L) x 80mm (H)
Maximum Fiber Optic Cable Lengths
Full-duplex Switch via Fiber:
Multi-mode Node to Node: 2000 m
Node to Hub 2000 m
Hub to Hub: 2000 m
Half-duplex Switch via Fiber:
Multi-mode Node to Node: 412 m
Node to Hub 412 m
Hub to Hub: 412 m
System Requirements
Pentium-class system with one available 32-bit PCI slot
Windows for Workgroups, Windows 95 or later,
Microsoft LAN Manager, OS/2 Warp, IBM LAN Server,
NetWare, IntraNetWare, or SCO UNIX operating system
Unpacking
Before installing your FiberOptic Card, verify that the following items
are included in the packaging carton:
FiberOptic Card
Two LAN driver diskettes
This Quick Installation Guide
Please notify your dealer if any item is damaged or missing.
2-1 Hardware Installation
No specific setup of your PCI FiberOptic Card is needed. Simply install
the card following the standard procedures for any PCI card.
General instructions for installing the card are provided below, since
the design of computer cases and motherboards varies. Refer to your
computer’s reference manual for further information, if needed.