Reset device to default
“TX ID” on TX unit and “TX connected ”on the RX
unit. Press both buttons simultaneously and hold
them down for 3 seconds to reset to default.
Computer control software (Windows)
1. Download software “HDbitT E-Matrix
Control center“ from http://www.hdbitt.
com/download-matrix/
2. Set PC’s IP to 192.168.1.xxx, then connect
your PC to the Ethernet switch which has
the same subnet with TX and RX units.
3. Open the software HDbitT E-Matrix Control
center and scan for devices.
• IP setting
TX and RX have their own default IP address, TX’s
IP is 192.168.1.238, and RX’s IP is 192.168.1.239.
Generally, there is no need to change the device
IP address, as the system can work normally
even though multiple TX units and multiple RX
units connected into the LAN have the same IP
address.
If IP change is required, follow the instructions on
the next page.
• Device setting
Set device name, ID, Channel then click "Update"
button to save conguration
• Pre-operation mode setting
Support
For more info or tech support
http://www.siig.com/support
April, 2018 Copyright © 2018 by SIIG, Inc. All rights reserved.
HDMI Over IP Extender with IR
User Guide
04-1129A
• Operation mode selection setting
Click “Select Mode” button and choose the mode
needed, then click "Update" button
Wireless Control APP
Requires installing a wireless access point on your
dedicated IGMP LAN.
• Download the Android or Apple wireless APP at
www.hdbitt.com/download-matrix
• Connect to the wireless access point which has
the same subnet as the TX and RX units
• TX ID, RX ID, TX connected number can be
reset by this APP, along with editing the device