Programming instructions
3
DoorCom IP 650-0
Siedle DoorCom IP links the Siedle
In-Home bus: Video with the IP
world. Door calls are transformed via
the DoorCom IP and transmitted via
the IP network (Intranet) to certain
PCs. The video image at the door
station is converted and transmitted
via the IP network.
The DoorCom IP Software Client
is used here as a virtual in-house
telephone for communication to the
door station.
The Software Client must be
installed on every PC in the network
which is intended to receive a door
call.
Switching and control commands
can be visualized and operated using
the Software Client.
Assignment of door calls to the
Software Clients takes place using
an IWA address (Interface Working
Address) which is entered in the
DoorCom IP with the aid of the
configuration software.
The door call can optionally also
be held over the telephone system
using a telephone, while the picture
is displayed by the Software Client
and all control functions such as
door release can also be initiated by
the software. For this, a DCA 740-01
must additionally be connected to
the DoorCom IP. The video camera
picture continues to appear in the
Software Client on the PC monitor.
Danger
Installation, mounting and
service work on electrical devices
may only be performed by
qualified electricians.
Failure to observe this regulation
could result in the risk of serious
damage to health or fatal injury
due to electric shocks.
• When working at the device,
observe the instructions for mains
cut-off.
• Observe the standard
DIN EN 60065!
When establishing the electronic
connection, observe the
requirements of VDE 0805 /
EN 60950.
• The building installation must
include an all-pole mains switch
with a contact separation of at least
3 mm.
• Ensure that the connection point
in the building installation is fused
with max. 16 A.
• When planning, the required
distributor space for switch panel
mounted devices must be taken into
account.
• External voltages >30 V AC/
DC must not be injected into the
in-house telephones.
Devices with 230 V connection
In accordance with DIN VDE 0100
Part 410, Section 411.1.3 ensure
that the DoorCom installation and
the mains voltage are securely
isolated. The sheathing of the
connection cable (safety extra-low
voltage) should only be stripped
back far enough to ensure that
reliable connection is possible.
1 System description
DoorCom IP 650-0
2 Safety remarks
System requirements
Find out about the necessary safety
measures and system requirements
before starting installation and
commissioning of the DoorCom IP.
System conditions for the bus
programming software
BPS 650-...
System requirements, software
conditions:
• IBM-compatible PC with CD-ROM
drive
• Intel Pentium III/1GHz, and
compatible CPUs
• Main memory with at least
512 MB RAM
• Powerful graphics card
• Operating systems from
Microsoft® Windows 2000/XP/
Vista/Windows 7
(no guarantee with Windows 95,
98SE and 98Me, and Windows NT
4.0 from SP3, as support for these
operating systems has now been
discontinued by Microsoft)
(currently also still without
engagement for Windows Vista, USB
drivers are already being reworked)
• Appr. 25 MB free space on the
hard disk (for BPS 650-... incl. help
file)
• Sufficient free storage space for
project data (appr. 5-250 kB per
project)
• Microsoft Internet Explorer 6.0 or
higher
• Acrobat Reader 7.0 or higher
• Where necessary up to 150 MB
free space on the hard disk for
additional service packs, Internet
Explorer, Acrobat Reader, etc.