Programming instructions
29
7 DoorCom
DCA 740-01
The DoorCom Analog DCA 740-...
is used as an interface between
DoorCom IP and an analog
telephone connection of a
telecommunication system.
It is possible to assign the maximum
number of possible users in a line to
the DCA 740-... . The functionality
depends in the main on the
capability of the telephone system /
on the telephones connected to it.
Assignments and functionality
for calls via the DCA 740-... are
saved in the SII 650-... . This can
be programmed using BPS 650-...
if the connection via DCA 740-... is
selected.
The selection of users and control
and switching functions takes place
by means of DTMF dialling. The
telecommunications system and
the connected telephones must
therefore possess DTMF dialling
capability.
Power supply
The DCA 740-... is supplied directly
from the SIVS 610-... . A separate
supply is consequently not required.
The power to the a/b public network
interface is supplied from the
telecommunication system or the
a/b public network connection from
the exchange. It is not possible to
connect an individual public network
telephone directly to the a/b line of
the DCA 740.
8 DoorCom IP
Factory setting IPVS 600-...
With the reset button at the
IPVS 600-... , it can be reset to the
as-delivered status. It is essential to
load the Siedle factory configuration
in the IPVS 600-... after a reset.
Proceed as follows.
1 Open the Internet Explorer.
2 Access the video server (IPVS) with
its IP address
3 Access the following menus in
sequence:
Setting
Service parameters
Firmware and configuration upload
4 Under Configuration upload,
select the configuration file with
„search...“. The file is on the
supplied CD.
5 Select the file with the rtc_image
with upload.
Using the Upload button, start the
update.