Programming instructions
24
6 Commissioning
DCIP 650-...
A number of steps have to be
executed for commissioning the
DCIP 650-... . The specified sequence
must be adhered to without fail.
• Prior to programming the
DoorCom IP 650-... the entire
In-Home system must be
programmed and documented with
the bus programming software
BPS 650-... .
• Complete programming of the
DoorCom IP 650-... takes place using
the bus programming software BPS
650-... via the SII 650-...
Issue of the IP address and
subnet mask in the IPVS 600-...
• The connection can be established
using a crossover network cable. The
IPVS 600-... can also be addressed
via the network if the PC and
IPVS 600-.. are located in the same
address area.
• Start the Internet Explorer on the
PC and enter the following in the
address line:
http://192.168.0.1
The IP settings in the as-delivered
status of the IPVS 600-...
IP address 192.168.0.1
Subnet mask 255.255.255.0
Gateway address 0.0.0.0
User name: Service
Password: None issued on
delivery
• The user interface is opened.
• In the user interface, select the
menu point Settings.
• On the left-hand side, select the
menu point Service parameters.
• Click the submenu Network. On
the right-hand side, the relevant
settings are opened up.
• The following settings can be
performed for operation in the
network.
IP address
Subnet mask address
Video transmission
HTTP browser port
Type of network connection
Changes to the IP address or subnet
mask address are transmitted to the
device by clicking on the Set button.
However, these only become valid
after restarting the device.
• After entering a new IP address,
click onto the Set button.
• Enter the old IP address in the
address line of the web browser,
followed by /reset (for example
192.168.0.1/reset). The IPVS is
restarted and can subsequently
only be reached using the new IP
address.
Step 1:
Read out In-Home bus
All existing devices within the
In-Home bus are read in and are
then visible in the BPS 650-... as a
tree structure. Each BVNG 650-...
possesses a unique address. This
must be set the same at the
SII 650-... and SIVS 610-... .
Step 2:
(only with multiple line system)
Manually add SII 650-...
In the BPS 650-... , select the
relevant line and add the SII 650-...
The address of BVNG 650-..., SIVS
610-... and SII 650-... must be set
the same. An already programmed
SII 650-... is automatically detected
by the BPS 650-... .
Connection of the PC to SII 650-...