Contents 1 System description 3 2 Safety remarks System requirements 3 3 3 Structure DCIP 650-... DCIP 650-... with DCA 740-... Terms 4 5 6 4 Components DoorCom IP Door loudspeakers, call buttons, Camera module 8 Input module 9 Programming, video server, DoorCom 10 Interfaces, Power supply 12 Interfaces, power supply 13 5 Installation wiring diagrams DCIP 650-0 Terminals DCIP 650-0 14 LED signalling IPVS 600-... 15 Block diagram SIVS 610-0 16 Block diagram SII 650-0 17 AS diagram AS-TVHa-1/1-...
1 System description DoorCom IP 650-0 2 Safety remarks System requirements DoorCom IP 650-0 Siedle DoorCom IP links the Siedle In-Home bus: Video with the IP world. Door calls are transformed via the DoorCom IP and transmitted via the IP network (Intranet) to certain PCs. The video image at the door station is converted and transmitted via the IP network. Danger Find out about the necessary safety measures and system requirements before starting installation and commissioning of the DoorCom IP.
3 Structure DCIP 650-0 In-Home bus: Video Audio and video communication via IP In-Home-bus: Video BVVU 650-... BVVU 650-... IPVS 600-0 TCP/IP-Network BVVU 650-... PRI 602-... USB VNG 602-... DCIP 650-... In-Home bus link for installation on PC users intended to receive door calls. The DCIP 650-... behaves in the system in the same way as one or more bus telephones and is consequently bound by the same system limitations (range and number of users). The DCIP 650-...
Autocommunication via the telephone system Video communication via IP In-Home-bus: Video telephone system BVVU 650-... BVVU 650-... IPVS 600-0 TCP/IP-Network BVVU 650-... PRI 602-... USB Prior to commissioning the DoorCom IP, the entire In-Home system must be programmed. The components SII 650-..., SIVS 610-... and BVNG 650-... which are in the same line must have the same address set. Programming of the SIVS 610-... and SII 650-... takes place with bus programming software BPS 650-...
3 Terms Client PC user connected to a network. Gateway Gateways link two different systems and create connections across network boundaries. During this process, both the physical transmission modes and also protocols and addresses are adjusted accordingly. Full duplex Two speaking users e.g. door station and remote station have an unrestricted speech connection. Open duplex communication, i.e. as opposed to the simplex speech mode.
USB The universal serial bus (USB) is a serial bus system for connection of a computer to external devices. Devices or storage media equipped with USB can be connected in running operation, and connected devices and their characteristics automatically detected. Vario-bus Various different input and control units can be connected to the Vario bus. It comprises 4 cores. The information on the Vario bus is transmitted via the RS485 protocol.
4 Components for DC IP 650-... Bus door loudspeaker module, bus call button modules, camera module BTLM 650-04 Bus door loudspeaker module for In-Home bus. Loudspeaker and microphone integrated, illuminated light button, integrated door release contact (DR) Contact load max. 15 V AC, 30 V DC, 2 A, switching time DR fixed at 3 seconds. Acoustic feedback when actuating the call buttons. BTM 650-01 - BTM 650-04 Bus call button modules for In-Home bus. 1-4 call buttons, integrated LED lighting.
4 Components for DC IP 650-... Input modules COM 611-02 Code lock module as an input unit in conjunction with the Siedle Vario bus. A C button for deleting incorrect inputs. An integrated LED can be used via an external potential-free contact as a status indication. Operating voltage 12 V AC /DC Current consumption max. 100 mA Ambient temperature -20°C to +70°C Dimensions: 99 x 99 mm DRM 611-0 Display call module as an input unit with 4-line display for placing door calls.
4 Components for DC IP 650-... Programming, video server, DoorCom IPVS 600-0 System interface video server Processing and adjustment of audio and video, transmission of data, audio and video to the IP network. Dimensions 112 x 85 x 40 mm DCA 740-01 The DoorCom Analog DCA 740-01 can be connected to a universal a/b interface. In conjunction with the DCIP 650-... it serves as an alternative speech connection if no speech connection via PC is preferred.
4 Components for DC IP 650-... Interfaces, power supply SIVS 610-0 System interface video server for connection of the In-Home bus: Video to IP video server. The SII 650-... is required for connection. Dimensions 144 x 130 x 55 mm SII 650-0 The system interface In-Home converts the signals from the InHome bus: Video for the SIVS 650-... Dimensions 107 x 89 x 60 mm VNG 602-... Video line rectifier in a 10-grid housing. Primary: 230 V AC, 50/60 Hz Secondary: 30 V DC, 1.1 A stabilized.
BPS 650-0 from V2.50 Bus programming software for programming In-Home bus systems. For this, the programming interface PRI 602-... is also required in conjunction with a BIM 650-... or the PRI 602-... USB. DCIP SC 600-0 DoorCom IP Software Client PC program which depicts a virtual in-house telephone with video on a PC monitor. Door communication with video to one or more door stations possible. Implementing switching and control functions e.g.
5 Terminals DCIP 650-... b a f g e d h c i j k Connections and LEDs IPVS 600-0 a No function b Junction box to the SIVS 610-... c RJ45 socket ETH network connection d Reset button to recreate the as-delivered status (after a reset, the Siedle modes must be reinstalled, see page 29.
5 LED display SIVS 610-... LED signalling IPVS 600-... The underneath of the IP video server IPVS 600-... has 3 LEDs which display operating statuses and can provide an indication of possible errors. LED operating status OFF Lights up in green Flashes green Lights up in red (briefly) Lights up in red (continuous) Function IPVS 600-... is switched off. IPVS 600-... is switched on Access to the IPVS 600-...
5 Terminals SIVS 610-0 Block diagram SIVS 610-0 G E4 E4 E4 E4 cvbv+ Da/Db + DR DR Li USP SN1 SN2 n1 n2 16 Reference for the inputs E1–E4 Input 4, not used Input 3, not used Input 2, not used Input 1, not used Pick off supply voltage for Vario bus, 15 V DC, max. 300 mA Vario bus Supply voltage 24-30 V DC Not used, DR via TLC 640-02 not used Not used RF signal, path SIM 740-... to SIVS 610-...
5 Terminals SII 650-0 Block diagram SII 650-0 TaM/TbM In-Home bus: Video Input and output E1+/E1Input for signalling function, 4-30 V DC or 4-20 V AC S1/S1 relay contact max. 24 V, 2 A SN1/GND RF signal Out SN2/GND RF signal In SaV/SbV In-Home bus internal connection bv/cv Terminal of the supply voltage for Vario bus Da/Db Vario bus LED signalling SII 650-... The system interface In-Home bus SII 650-...
c b TR 603-... a) Siedle-Vario BCMC 650-... BTLM 650-... BTM 650-... c) Remarks L1 N c c Tö 12 V AC min. 20 Ohm b b GND Vc Tb Ta Ta Tb Vc GND Device requirement BTM IN BTLM TaK TbK b) BVNG 650-... ZBVNG 650-... L1 N Sb Sa Tö Tö Li Li TaM TbM TaK TbK PRI 602-... USB SII 650-... Sb Sa Db Da cv bv M1 GND SN2 SN1 S1 S1 E1+ E1- TaM TbM TaM TbM VNG 602-...
In-Home bus: Video Single line system AS-TVHa-1/1 with DCIP 650-... Functional characteristics Up to 29 PC users (Software Clients) of a network can be called from the door station. Calling, speech and door release via the Software Client DCIP SC 600-... . The Software Client must be installed on every PC which receives calls. Call functions of the Software Client 3-tone chime as standard, a dedicated *.wav file can be assigned for each call tone.
TR 603-... a) Siedle-Vario BCMC 650-... BTLM 650-... BTM 650-... c) Remarks L1 N c c Tö 12 V AC min. 20 Ohm b b GND Vc Tb Ta Ta Tb Vc GND b c Device requirement BTM IN BTLM TaK TbK b) BVNG 650-... ZBVNG 650-... L1 N Sb Sa Tö Tö Li Li TaM TbM TaK TbK PRI 602-... USB SII 650-... Sb Sa Db Da cv bv M1 GND SN2 SN1 S1 S1 E1+ E1- TaM TbM TaM TbM VNG 602-...
In-Home bus: Video Single-line system with DCA 740-... AS-TVHa-1/1 with DCIP 650-... Remarks a) The TR 603-... (12 V AC, 1.3 A) Functional characteristics can supply 1 door release button Up to 29 PC users (Software Clients) and max. 24 bus call button modules of a network can be called from with LED lighting (BTM 650-01, -02, the door station. Calling and door -03 and -04). release via the Software Client With more than 24 illuminated bus DCIP SC 600-... .
TR 603-... a) Siedle-Vario BCMC 650-... BTLM 650-... BTM 650-... c) Remarks L1 N c c Tö 12 V AC min. 20 Ohm b b GND Vc Tb Ta Ta Tb Vc GND b c Device requirement BTM IN BTLM TaK TbK b) BVNG 650-... ZBVNG 650-... ZBNG 650-... L1 N SbV SaV Sb Sa Tö Tö Li Li TaM TbM TaK TbK PRI 602-... USB SII 650-... Sb Sa Db Da cv bv M1 GND SN2 SN1 S1 S1 E1+ E1- TaM TbM TaM TbM VNG 602-...
In-Home bus: Video Multiple line system AS-TVHa-1/1 with DCIP 650-... Functional characteristics Up to 29 PC users (Software Clients) in a network can be called per SII 650-... . In a multiple-line system, several lines are connected. The line address must be set the same at each BVNG 650-..., SIVS 610-... and SII 650-... . In each line, a maximum of one DCIP 650-... may be used. In a multiple-line system with 2 lines, this means that 60 users can be called form a door station.
6 Commissioning DCIP 650-... A number of steps have to be executed for commissioning the DCIP 650-... . The specified sequence must be adhered to without fail. • Prior to programming the DoorCom IP 650-... the entire In-Home system must be programmed and documented with the bus programming software BPS 650-... . • Complete programming of the DoorCom IP 650-... takes place using the bus programming software BPS 650-... via the SII 650-... Connection of the PC to SII 650-...
Step 3 Create virtual users In the first table DCIP-SC (virtual users) create the users. Each user should be given a unique name wherever possible such as Secretarial. Step 4 In the tree structure of the BPS 650-... , select the relevant door station and assign the users to the previously created call buttons. Subsequently transfer the configuration to SII 650-.../ SIVS 610-... . Step 5: In the tree structure of the BPS 650-..., select the SII 650-... . Pressing the Configuration button in the DCIP-SC...
7 Client-Software DCIP SC 600-... Installation of the Software Clients The Software Client DCIP SC 600-... (Ver. 1.1. or higher) must be installed on each PC which is intended to receive door calls. The Software Client communicates with the remote station, the DCIP 650-... Following the installation, the file (*.dcip) generated by the bus programming software BPS 650-... must be imported. The addresses to which the client is intended to respond are selected from the imported file.
Possible error sources • No speech connection from the PC to the door. The microphone amplifier may not be activated. • Installation must take place as administrator, so that all registered users have access to the Software Client later. • Marked echo on the line in speech mode. In the Windows volume regulation for sound reproduction, Sound off must be activated under the microphone controller. This selection prevents the PC microphone signal being reproduced in the PC loudspeaker.
7 DoorCom DCA 740-01 8 DoorCom IP Factory setting IPVS 600-... The DoorCom Analog DCA 740-... is used as an interface between DoorCom IP and an analog telephone connection of a telecommunication system. With the reset button at the IPVS 600-... , it can be reset to the as-delivered status. It is essential to load the Siedle factory configuration in the IPVS 600-... after a reset. Proceed as follows. 1 Open the Internet Explorer.
9 Servicing Measured values Measurement values for DoorCom IP, to be measured using a digital multimeter Idle status min. max. Voltage +/ at the SIVS 610-... 24 V DC 30 V DC Current consumption 500 mA Conductor lengths VNG 602-... supplies 1 DCIP 650-... 100 m VNG 602-... supplies 2 DCIP 650-...
Index 10 Glossary Terminals Wiring diagram As-delivered status Block diagram Client Config DoorCom Commissioning IP IP address IWA LED display Licences Line rectifier Programming Server Software Client Subnet mask System interface video server System requirements TCP Power supply Factory setting 14 18 29 18 26 24 10 24 6 6 6 15 26 12 24 8 26 6 15 2, 26 6 4, 6 29 BTLM 650-04 BTM 650-... BCMC 650-... BPS 650-0 BVNG 650-... COM 611-... DCA 740-... DCIP SC 600-0 DRM 611-... IPVS 600-0 PRI 602-...