Programming instructions
19
Function
Up to 29 PC users (Software Clients)
of a network can be called from the
door station. Calling, speech and
door release via the Software Client
DCIP SC 600-... . The Software
Client must be installed on every PC
which receives calls.
Call functions of the Software Client
3-tone chime as standard, a dedi-
cated *.wav le can be assigned for
each call tone.
It is not possible to listen in to an
existing call from other PC users in
the network. The door is opened by
the called PC user using a “virtual
door release button”, the light
switching function is actuated using
a “virtual light button”. The door
call can be muted with an optical
display on the monitor.
Supplementary functions
• Additional PC users can be imple-
mented with an additional line.
• Up to 10 PC users can be called in
parallel with a call button from the
door station. Up to 49/45 PC users
are possible at one IPVS 600-... .
Reduction to 45 PC users can result
if 10 or more PC users are cong-
ured as parallel devices.
In-Home bus Video
Single line system
Remarks
a) The TR603-... (12VAC, 1.3A)
can supply 1door release button
and max.24bus call button modules
with LED lighting (BTM650-01,
-02, -03 and -04). With more than
24illuminated bus call button
modules, an additional TR603-... is
required.
Current consumers in the AS
diagram:
Door release appr. 600 mA
Camera heating 100 mA
LED lighting
Per bus call button module 25mA
b) Door release contact load in the
bus video line rectifier BVNG 650-...
max. 15 V AC, 30 V DC, 2 A.
• Light contact load in the bus video
line rectifier max. 15VAC, 30VDC,
2A.
c) Door release 12 V AC, use at least
20Ohm (e.g. TÖ615-...).
f) Distance of the BVNG650-.../
SII650-... to the door station max.
100 m with J-Y(ST)Y 0.8mm core
material. During installation, ensure
that the door release is laid in a
separate cable. Supply voltage
available from SIVS610-... at the
terminals bv+/cv- 12 V DC, max.
300mA.