Use and Care Manual
Table Of Contents
10
INSTALLATION
MINIMUM CLEARANCE TO COMBUSTIBLES
RearFrontBottomTop*Left/RightModel
0 in. to Spacer36 in.3 in.36 in.8 in.Blue Flame
0 in. to Spacer36 in.10 in.36 in.8 in.Infrared
Top clearance is from top heater to ceiling, wood shelf or other combuible material
Bottom clearance is from bottom of heater to surface of carpet, tile or other combuible material.
A second side wall must be at least 18 in. away from the other side of the heater.
Always maintain a minimum of 36 in. clearance from furniture and draperies.
For installation in residential garages please refer to page 4.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your
primary heating system. Do not install this heater as your primary heat source.
Do not install this heater in a bathroom or bedroom.
WARNING: A qualied technician must install heater. Follow all local codes.
WARNING: Maintain the minimum clearances. If possible, provide greater clearances from the
oor, ceiling, and adjoining wall than required.
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces
next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater
where impurities (such as tobacco smoke, candles, cleaning uids, oil or kerosene lamps, etc.)
in the air exist, may cause walls to discolor.
CLEARANCES TO COMBUSTIBLES
Carefully follow the instructions below. This heater can be mounted on the wall or on the oor
using the support legs provided separately.
WARNING: Maintain the minimum clearances shown (see Fig. 3). If you can, provide greater
clearances from oor, ceiling, and joining wall.
Fig. 3B: Mounting clearances as viewed from
front of heater (inches) - Blue Flame
Fig. 3A: Mounting clearances as viewed from
front of heater (inches) - Infrared
CEILING: 36 in. Minimum
LEFT SIDE:
8 in.
Minimum
from Side of
Heater
RIGHT SIDE:
8 in.
Minimum
from Side of
Heater
FLOOR: 10 in. Minimum to Top Surface of Carpeting
Tile from the Other Combustible Material
CEILING: 36 in. Minimum
LEFT SIDE:
8 in.
Minimum
from Side of
Heater
RIGHT SIDE:
8 in.
Minimum
from Side of
Heater
FLOOR: 3 in. Minimum to Top Surface of Carpeting
Tile from the Other Combustible Material