Instruction Manual

page6/9/2022 3
!
ATTENTION: Install in accordance with local and national building and electric codes.
4
Install Joiner Aligners
In the joining fixtures install the joiner
aligners in the trim extrusion to
approximately halfway
Dimple
engaged.
Important: To insert aligners, tap gently
with a hammer until half is inserted into
the joiner channel. Be sure to engage the
dimple.
8
Install CAT6 Cables
Install CAT6 cables and desired location.
NOTE: For Standalone fixtures skip to step 7
5
Open Slots for Joiner
Brackets
Snap off the safety cover on joiner brackets
slots with a flat head screw driver. This only
needs to be done one sides that require
joining.
7
Secure Fixture on the Grid
Secure the fixture to T-bar the Grid.
For continuous runs, finish installing run first
and then secure to the T-Bar grid.
6
Install Joiner Brackets
Install supplied side attachment brackets
with 3/8” nut driver.
TruGroove Recessed Micro T-Grid Installation Instructions
ID-23
Install seismic restraints according to local
building code requirements.
9
Install Seismic Restraints