User`s manual
46
Cable Error
Messages
MISWIRE
The tester displays miswire if it senses a contact that should have a valid connection is instead
connected to a wrong contact.
As shown in this example, the miswire error is always indicated as a contact OPEN to where it
should go, and MISWIRE to where it does go.
Wiring mistakes in the cable cause miswires.
HIGH RESISTANCE ERROR
The tester displays a High Resistance Error when it senses a cable interconnection has too
much resistance.
Possible causes are:
Defects in the cable such as partially inserted or dirty connector contacts, and poorly
crimped wires.
High resistance in the adapter or tester connector contacts. In this case, the adapters
or tester connectors that interface with the adapters may be worn or damaged and
need to be replaced.
A Connection Resistance setting is too low for the tested assembly. In this case, the
resistance of a wire or a contact is greater than the Connection Resistance setting but
less than the LV Insulation Resistance setting.
A component such as a resistor exists in the cable, which has not been learned in the
test program.
ERROR:E8C464-2X8NH
NET 1: OPEN
J1-001 TO J3-001
MISWIRE J3-002
NET 1
NET 2
1
2
1
2
J3
J1
J1
1
2
J3
1
2
ERROR:E8C464-2X8NH
NET 2: OPEN
J1-002 TO J3-002
MISWIRE J3-001
and these were the errors,
the detailed errors would be like these.
For example, if this is correct