Product Datasheet/Brochure

Page 3 of 5 | Eective 1/18
30" (762 mm)
finished width
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
SINGLE COLUMN
4"
(102 mm)
finished
return*
TOP VIEW
INSTALLATION CLEARANCES
SKSCR3001P
30" INTEGRATED
REFRIGERATOR COLUMN
90°
115°
24"
(610 mm)
15 7/16"*
(392 mm)
(867 mm)
29 3/4"
(756 mm)
29 3/4"
3/4"
(19 mm)**
**
Varies depending on the
thickness of the custom
cabinet panel. 3/4"
(19 mm)
is relevant when using the
Stainless Steel Door Panel
Kit (optional accessory).
Door handle must be
added to this dimension.
*
(756 mm)
30" cutout
(762 mm)
1/8"
(3 mm)
1/8"
min.
min.
(3 mm)
v.11 p1
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
1 3/8"
(35 mm)
A minimum 4" (102 mm) finished return that matches the cabinet
exterior is recommended on all sides and the top of the cutout
opening. The shaded area will be visible after installation.
*
25" (635 mm)
min. depth
flush install
24"
(610 mm)
min. depth
proud install
84"
(2134 mm)
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
Notes
Refrigerator can be installed ush or proud with 3/4" custom
panel or optional stainless steel panel kit.
Flush – With a 25" (635 mm) cutout depth, the front face of
the refrigerator ts ush with 25" (635 mm) depth adjacent
cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face of
the refrigerator extends approximately 3/4" (19 mm) beyond
24" (610 mm) depth adjacent cabinets.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water Line
A cold water supply is required for water dispenser
operation. Water pressure must be between 20 and 120 p.s.i.
Tubing should be long enough to extend to the front of the
refrigerator. Allow enough tubing to accommodate a bend
leading into the water line connection.
Water line can enter an opening through oor or back wall.
SINGLE COLUMN
Notes
Door Swing Clearances – The installation must allow for
clearances to adjacent walls or cabinets. This refrigerator is
equipped with a 2-position door stop. The factory-set 11
door swing can be adjusted to 90° if clearance to adjacent
cabinets or walls is restricted.
Door Handle Clearances – The Door Handle depth must
be added to the dimension noted to determine the total
clearances required from adjacent cabinets or walls. This
clearance will vary depending on the custom handle used.
When using the Stainless Steel Door Panel Kit w/Handle or
the Brushed Aluminum Handle (optional accessories), the
door handle clearance with door open 115° is 18" (457 mm).
INSTALLATION CLEARANCES
TOP VIEW
30" (762 mm)
finished width
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
SINGLE COLUMN
4"
(102 mm)
finished
return*
TOP VIEW
INSTALLATION CLEARANCES
SKSCR3001P
30" INTEGRATED
REFRIGERATOR COLUMN
90°
115°
24"
(610 mm)
15 7/16"*
(392 mm)
34 1/8"
(867 mm)
29 3/4"
(756 mm)
29 3/4"
3/4"
(19 mm)**
**
Varies depending on the
thickness of the custom
cabinet panel. 3/4"
(19 mm)
is relevant when using the
Stainless Steel Door Panel
Kit (optional accessory).
Door handle must be
added to this dimension.
*
(756 mm)
30" cutout
(762 mm)
1/8"
(3 mm)
1/8"
min.
min.
(3 mm)
v.11 p1
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
1 3/8"
(35 mm)
A minimum 4" (102 mm) finished return that matches the cabinet
exterior is recommended on all sides and the top of the cutout
opening. The shaded area will be visible after installation.
*
25"
(635 mm)
min. depth
flush install
24"
(610 mm)
min. depth
proud install
84"
(2134 mm)
SKSCR3001P
30-INCH INTEGRATED COLUMN
REFRIGERATOR