Specification Sheet

SKSMD2401S
MICROWAVE OVEN DRAWER
TRUE FLUSH INSTALLATION – REQUIRES DEFLECTOR VENT (KIT INCLUDED)
Page 5 of 6 | Effective 7/20 | WCAG
1 9/64" (29 mm)
Door Thickness
15" (381 mm)
Auto Drawer
Opening
4 11/16" (119 mm)
1 3/4" (44 mm)
4" (102 mm)
21 5/8"
(549 mm)
14 19/32"
(371 mm)
21 7/8" (556 mm)
23 7/8"
(606 mm)
15 7/8"
(403 mm)
Anti-Tip Block
*Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided
electrical cord can reach. Power cord access hole in cabinet should be a minimum 1 1/2" (38 mm) diameter
hole and deburred of all sharp edges.
Suggested electrical
outlet location*
6" (152 mm)
5" (127 mm)
4" (101 mm)
3 1/2" (89 mm)
15 9/16"
(395 mm)
36" (914 mm)
Countertop
Height
24" (914 mm)
Cabinet Minimum
23 1/2"
(597 mm)
Minimum
Depth
B
D
C
A
A
22 1/8"
(562 mm)
14 13/16" (376 mm)
to Bottom of Anti-Tip Block
C - Allow 7/16" (11 mm) minimum space
A - Allow 7/8"
(22 mm) overlap
B - Allow 3/16"
(5 mm) overlap
D - Allow 1/8"
(3 mm) overlap
Standard (Proud) InstallationOverall Product Dimensions
Mounting Screw Location
Flush Installation
*Can also be installed using an electrical outlet in an adjacent cabinet within the
area where the provided electrical cord can reach. Power cord access hole in
cabinet should be a minimum 1 1/2"
(38 mm) diameter hole and deburred of all
sharp edges.
Anti-Tip Block
Suggested electrical
outlet location*
4"
(101 mm)
3 1/2" (89 mm)
6" (152 mm)
23 1/2" (597 mm)
Minimum Depth
16 7/8" (429 mm)
14 13/16" (376 mm)
to Bottom of Anti-Tip Block
5" (127 mm)
24 3/16" (614 mm) Minimum
24 1/2" (622 mm) Maximum
1 1/16" (27 mm)
1 3/4" (44 mm)
22 1/8"
(562 mm)
1 3/4"
(44 mm)
Note: the face of the
shelf must sit 1 3/4"
(44.4 mm) back from
the face of the cabinet.
Shelf
face
Cabinet face
Note: the mounting surface of the
finished cleat must sit 1 1/16" (27 mm)
back from the face of the cabinet (pushing
the face of the drawer out 1/4" (6 mm))
Anti-Tip Block
Cabinet face
Drawer
face
Mounting
cleat
Top view
22 1/8"
(562 mm)
Mounting cleat
opening width
C
L
True Flush Installation
16 7/8"
(429 mm)
Note: The mounting surface of the
finished cleat must sit 1 5/16" (33 mm)
back from the face of the cabinet.
Top view
C
L
Cabinet face
Drawer
face
Mounting
cleat
Anti-Tip Block
*Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach.
Power cord access hole in cabinet should be a minimum 1 1/2" (38 mm) diameter hole and deburred of all sharp edges.
22 1/8"
(562 mm)
Mounting cleat
opening width
Mounting
Flange
Flush Installation Deflector Vent
Side View
Front
Face of
Cabinet
16 7/8"
(429 mm)
Flush
Opening
Height
3/4" (19 mm)
Shelf
1 3/4" (44 mm)
Front Face of Shelf
Anti-Tip Block
No Oven
Front View
Suggested
Electrical
Outlet
Location
Anti-Tip Block
3/4" (19 mm)
Shelf
22 1/8" (562 mm)
Mounting Cleat Opening Width
24 3/16" (614 mm) Min
24 1/2" (622 mm) Max
Flush Opening Width
Shelf detail showing the deflector vent installed.
Shelf detail showing the deflector vent
during installation.
Position deflector vent and mark holes.
Pre drill using a 1/16" (1.57 mm) bit before mounting.
Notes
In the true ush application, the appliance is mounted just as described, truly ush with the cabinet face. However, due to
the appliance face and the cabinet face being on the same plane, the cabinet cutout edges will be visible and exposed. It
is recommended in this true ush installation to nish / stain these edges.
TRUE FLUSH INSTALLATION – REQUIRES DEFLECTOR VENT (KIT INCLUDED)