SKSCF2401P
24" INTEGRATED
FREEZER COLUMN
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION 
SINGLE COLUMN
INSTALLATION CLEARANCES
TOP VIEW
**
Varies depending on the 
thickness of the custom 
cabinet panel. The door 
panels in the optional 
Signature Kitchen Suite 
stainless steel door panel 
kit are 3/4" (19 mm) thick.
Door handle must be 
added to this dimension.
 *
24" (610 mm) 
finished width
4"
(102 mm)
finished
return*
25" (635 mm)
min. depth 
flush install
24"
 (610 mm)
min. depth
proud install
84"
(2134 mm)
5"
(127 mm)
electrical
location
A minimum 4" 
(102 mm) finished return that matches the cabinet 
exterior is recommended on all sides and the top of the cutout 
opening. The shaded area will be visible after installation.
*
4"
(102 mm)
water
location
1 3/8"
(35 mm)
1/8"
(3 mm)
min.
1/8"
min.
(3 mm)
90°
115°
11 3/8"*
(288 mm)
24"
(610 mm)
26 1/4"
(666 mm)
24"
23 3/4"
(603 mm)
3/4"
(19 mm)**
(610 mm)
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
Notes
Freezer can be installed ush or proud with 3/4" custom panel 
or optional stainless steel panel kit.
Flush – With a 25" (635 mm) cutout depth, the front face 
of the freezer ts ush with 25" (635 mm) depth adjacent 
cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face  
of the freezer extends approximately 3/4" (19 mm) beyond 24" 
(610 mm) depth adjacent cabinets.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded 
3-prong electrical receptacle recessed into the back wall. 
Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water Line
A cold water supply is required for automatic icemaker 
operation. Water pressure must be between 20 and 120 p.s.i. 
Tubing should be long enough to extend to the front of the 
freezer. Allow enough tubing to accommodate a bend leading 
into the water line connection.
Water line can enter an opening through oor or back wall.
Install a shut-o valve between the icemaker water valve and 
cold water supply in the home.
SINGLE COLUMN
Notes
Door Swing Clearances – The installation must allow for 
clearances to adjacent walls or cabinets. This freezer is 
equipped with a 2-position door stop. The factory-set 115° 
door swing can be adjusted to 90° if clearance to adjacent 
cabinets or walls is restricted.
Door Handle Clearances – The Door Handle depth must 
be added to the dimension noted to determine the total 
clearances required from adjacent cabinets or walls. This 
clearance will vary depending on the custom handle used. 
When using the Stainless Steel Door Panel Kit w/Handle or 
the Brushed Aluminum Handle (optional accessories), the 
door handle clearance with door open 115° is 14" (356 mm).
INSTALLATION CLEARANCES
TOP VIEW
SKSCF2401P
24" INTEGRATED
FREEZER COLUMN
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION 
SINGLE COLUMN
INSTALLATION CLEARANCES
TOP VIEW
**
Varies depending on the 
thickness of the custom 
cabinet panel. The door 
panels in the optional 
Signature Kitchen Suite 
stainless steel door panel 
kit are 3/4" (19 mm) thick.
Door handle must be 
added to this dimension.
 *
24" (610 mm) 
finished width
4"
(102 mm)
finished
return*
25"
 (635 mm)
min. depth 
flush install
24"
 (610 mm)
min. depth
proud install
84"
(2134 mm)
5"
(127 mm)
electrical
location
A minimum 4" 
(102 mm) finished return that matches the cabinet 
exterior is recommended on all sides and the top of the cutout 
opening. The shaded area will be visible after installation.
*
4"
(102 mm)
water
location
1 3/8"
(35 mm)
1/8"
(3 mm)
min.
1/8"
min.
(3 mm)
90°
115°
11 3/8"*
(288 mm)
24"
(610 mm)
26 1/4"
(666 mm)
24"
23 3/4"
(603 mm)
3/4"
(19 mm)**
(610 mm)
SKSCF2401P
24-INCH INTEGRATED COLUMN FREEZER 