Operator`s manual
Table Of Contents
- 1.0 Introduction
- 2.0 Specifications
- 2.1 DC Voltage Measurement
- 2.2 DC Current Measurement
- 2.3 Resistance Measurements
- 2.4 AC Voltage Measurements
- 2.5 AC Current Measurement, True RMS
- 2.6 Leakage Measurement (SMU2064)
- 2.7 RTD Temperature Measurement
- 2.8 Thermocouple Temperature Measurement
- 2.9 Additional Component Measurement Capability
- 2.10 Time Measurements
- 2.11 Trigger Functions
- 2.12 Measurement Times
- 2.12.1 Measurement Apertures and Read Interval
- 2.12.2 Range and Function Transition Times
- Range switching within Volts DC, using DMMSetRange()
- Range switching in Resistance (2-W or 4-W), using DMMSetRange()
- Switching between VDC and Resistance, using DMMSetFuncRange()
- Switching between Ohms and IDC, using DMMSetFuncRange()
- Switching between VDC and Capacitance, using DMMSetFuncRange()
- Switching between Ohms and Capacitance, using DMMSetFuncRange()
- Switching ranges within DC Current using DMMSetRange()
- Switching Capacitance ranges using DMMSetRange()
- 2.13 Source Functions (2064)
- 2.14 Accuracy Notes
- 2.15 Other Specifications
- 3.0 Getting Started
- 4.0 DMM Operation and Measurements Tutorial
- 4.1 Voltage Measurement
- 4.2 Current Measurements
- 4.3 Resistance Measurements
- 4.3.1 2-Wire Ohm Measurements
- 4.3.2 4-Wire Ohm Measurements
- 4.3.3 Using Offset Ohms function (SMU2064)
- 4.3.4 6-wire Guarded Resistance Measurement (SMU2064)
- 4.3.5 Extended Resistance Measurements (SMU2064)
- 4.3.6 Effects of Thermo-Voltaic Offset
- 4.3.7 Guarding High Value Resistance Measurements (SMU2064)
- 4.4 Leakage Measurements (SMU2064)
- 4.5 Anatomy of measurement timing
- 4.6 RTD Temperature Measurement (SMU2064)
- 4.7 Internal Temperature (SMU2064)
- 4.8 Diode Characterization
- 4.9 Capacitance Measurement, Charge Balance method
- 4.10 In-Circuit Capacitance Measurement (SMU2064)
- 4.11 Measuring the resistance in a series RC network (2064)
- 4.12 Inductance Measurement (SMU2064)
- 4.13 Characteristic Impedance Measurement (SMU2064)
- 4.14 Trigger Operation
- 4.15 Time and Frequency Measurements
- 4.16 Source Functions (2064)
- 4.17 Interfacing to an external device
- 4.18 Measuring Thermocouples’ Temperature
- 4.19 Auxiliary VDC inputs (2064)
- 5.0 Windows Interface
- 5.1 Distribution Files
- 5.2 Using the SMU2060 Driver With C++ or Similar Software
- 5.3 Visual Basic DMM Panel Application
- 5.4 Windows DLL Default Modes and Parameters
- 5.5 Using the SMU2060 DLL with LabWindows/CVI
- 5.6 Windows Command Language
- DMMArmAnalogTrigger
- DMMArmTrigger
- DMMBurstBuffRead
- DMMBurstRead
- DMMCalibrate
- DMMCleanRelay
- DMMClearMinMax
- DMMCloseUSB
- DMMDelayedTrigger
- DMMDisableTrimDAC
- DMMDisarmTrigger
- DMMDutyCycleStr
- DMMErrString
- DMMFrequencyStr
- DMMGetACCapsR
- DMMGetAperture
- DMMGetAverageVAC
- DMMGetBufferSize
- DMMGetBusInfo
- DMMGetCalDate
- DMMGetdB
- DMMGetdBStr
- DMMGetCJTemp
- DMMGetCounterRange
- DMMGetDeviation
- DMMGetDeviatStr
- DMMGetDevLocation
- DMMGetDiffMnMxStr
- DMMGetFuncRange
- DMMGetFunction
- DMMGetGrdVer
- DMMGetHwVer
- DMMGetHwOption
- DMMGetID
- DMMGetLowFreqVRMS
- DMMGetManDate
- DMMGetMax
- DMMGetMaxStr
- DMMGetMin
- DMMGetMinStr
- DMMGetNumDevices
- DMMGetRange
- DMMGetReadInterval
- DMMGetSourceFreq
- DMMGetStoredReading
- DMMGetSourceMode
- DMMGetTCType
- DMMGetTrigger
- DMMGetTriggerInfo
- DMMGetType
- DMMGetVer
- DMMInit
- DMMIsAutoRange
- DMMIsInitialized
- DMMIsRelative
- DMMLongTrigger
- DMMLongTrigRead
- DMMOpenCalACCaps
- DMMOpenTerminalCal
- DMMOpenUSB
- DMMOutputSync
- DMMPeriodStr
- DMMQuickInit
- DMMRead
- DMMReadBuffer
- DMMReadBufferStr
- DMMReadCJTemp
- DMMReadCrestFactor
- DMMReadDutyCycle
- DMMReadSR
- DMMReadFrequency
- DMMReadHiLoSense
- DMMReadHiSense
- DMMReadInductorQ
- DMMReadInductorR
- DMMReadLoSense
- DMMReadMeasurement
- DMMReadMedian
- DMMReadNorm
- DMMReadNsamples
- DMMReadPeakToPeak
- DMMReadPeriod
- DMMReadStr
- DMMReadTestV
- DMMReadTotalizer
- DMMReadWidth
- DMMReady
- DMMSetACCapsDelay
- DMMSetACCapsLevel
- DMMSetACVSource
- DMMSetAperture
- DMMSetAutoRange
- DMMSetBuffTrigRead
- DMMSetCapsAveSamp
- DMMSetCJTemp
- DMMSetCompThreshold
- DMMSetCounterRng
- DMMSetDCISource
- DMMSetDCVSource
- DMMSetFastRMS
- DMMSetFuncRange
- DMMSetFunction
- DMMSetInductFreq
- DMMSetOffsetOhms
- DMMSetPLC
- DMMSetPulseGen
- DMMSetRange
- DMMSetReadInterval
- DMMSetReference
- DMMSetRelative
- DMMSetRTD
- DMMSetSensorParams
- DMMSetSourceMode
- DMMSetSourceRes
- DMMSetSync
- DMMSetTCType
- DMMSetTempUnits
- DMMSetTrigPolarity
- DMMSetTrigRead
- DMMSetTrimDAC
- DMMStartTotalizer
- DMMStopTotalizer
- DMMTerminate
- DMMTrigger
- DMMTriggerBurst
- DMMUnlockCounter
- DMMWaitForTrigger
- DMMWidthStr
- 5.7 Calibration and Service Commands
- 5.8 Service Commands
- 5.9 Error Codes
- 5.10 Warning Codes
- 5.11 Parameter List
- 6.0 Maintenance
- 7.0 Warranty and Service
- 8.0 Accessories
Signametrics 66
Declare Function DMMSetAperture Lib "SMU2060.dll" (ByVal nDmm As Long, ByVal nAperture As Long) _
As Long
Declare Function DMMSetFunction Lib "SMU2060.dll" (ByVal nDmm As Long, ByVal nFunc As Long) As Long
Declare Function DMMSetRange Lib "SMU2060.dll" (ByVal nDmm As Long, ByVal nRange As Long) As Long
Declare Function DMMRead Lib "SMU2060.dll" (ByVal nDmm As Long, dResult As Double) As Long
' Definitions from USBDMMUser.h
' for DMMSetFunction()
Global Const VDCFunc = 0
Global Const VACFunc = 4
Global Const Ohm2Func = 21
Global nDmm as Long
' for DMMSetRange()
Global Const Range0 = 0
Global Const Range1 = 1
Global Const Range2 = 2
Global Const Range3 = 3
'Measurement Apertures for use with DMMSetAperture()
Global Const APR_1p0666s = 4 '1.07s
Global Const APR_p96s = 5 '960ms Aperture
Global Const APR_p5333s = 6 '533ms
Global Const APR_p48s = 7 '480ms
Global Const APR_p2666s = 8 '266ms
Global Const APR_p16s = 9 '160ms
Global nDmm As Long ' Global store for the DMM number
SimplePanel.frm Form file contents:
Private Sub Form_Load() 'Fomr_Load allways gets executed first.
Dim i As Long
nDmm = 0 ‘Set to first DMM in the system
i = DMMInit(nDmm,"C:\SM60CAL.dat") 'Initialize and load cal file
i = DMMSetFunction(nDmm, VDCFunc) 'Set DMM to DCV function
i = DMMSetRange(nDmm, Range2) 'Select the 24V range
i = DMMSetAperture(nDmm, APR_p16s) 'Set measurement Aperture to 160ms
End Sub
Private Sub ReadBotton_Click() 'Read Botton Click action.
Dim i As Long 'Any time this botton is pressed
Dim dReading As Double 'the DMM takes a reading and displays it.
i = DMMRead(nDmm, dReading) 'Take a reading
TextReading.Text = dReading 'display it in a Text box.
End Sub