Operator`s manual
Table Of Contents
- 1.0 Introduction
- 2.0 Specifications
- 2.1 DC Voltage Measurement
- 2.2 DC Current Measurement
- 2.3 Resistance Measurements
- 2.4 AC Voltage Measurements
- 2.5 AC Current Measurement, True RMS
- 2.6 Leakage Measurement (SMU2064)
- 2.7 RTD Temperature Measurement
- 2.8 Thermocouple Temperature Measurement
- 2.9 Additional Component Measurement Capability
- 2.10 Time Measurements
- 2.11 Trigger Functions
- 2.12 Measurement Times
- 2.12.1 Measurement Apertures and Read Interval
- 2.12.2 Range and Function Transition Times
- Range switching within Volts DC, using DMMSetRange()
- Range switching in Resistance (2-W or 4-W), using DMMSetRange()
- Switching between VDC and Resistance, using DMMSetFuncRange()
- Switching between Ohms and IDC, using DMMSetFuncRange()
- Switching between VDC and Capacitance, using DMMSetFuncRange()
- Switching between Ohms and Capacitance, using DMMSetFuncRange()
- Switching ranges within DC Current using DMMSetRange()
- Switching Capacitance ranges using DMMSetRange()
- 2.13 Source Functions (2064)
- 2.14 Accuracy Notes
- 2.15 Other Specifications
- 3.0 Getting Started
- 4.0 DMM Operation and Measurements Tutorial
- 4.1 Voltage Measurement
- 4.2 Current Measurements
- 4.3 Resistance Measurements
- 4.3.1 2-Wire Ohm Measurements
- 4.3.2 4-Wire Ohm Measurements
- 4.3.3 Using Offset Ohms function (SMU2064)
- 4.3.4 6-wire Guarded Resistance Measurement (SMU2064)
- 4.3.5 Extended Resistance Measurements (SMU2064)
- 4.3.6 Effects of Thermo-Voltaic Offset
- 4.3.7 Guarding High Value Resistance Measurements (SMU2064)
- 4.4 Leakage Measurements (SMU2064)
- 4.5 Anatomy of measurement timing
- 4.6 RTD Temperature Measurement (SMU2064)
- 4.7 Internal Temperature (SMU2064)
- 4.8 Diode Characterization
- 4.9 Capacitance Measurement, Charge Balance method
- 4.10 In-Circuit Capacitance Measurement (SMU2064)
- 4.11 Measuring the resistance in a series RC network (2064)
- 4.12 Inductance Measurement (SMU2064)
- 4.13 Characteristic Impedance Measurement (SMU2064)
- 4.14 Trigger Operation
- 4.15 Time and Frequency Measurements
- 4.16 Source Functions (2064)
- 4.17 Interfacing to an external device
- 4.18 Measuring Thermocouples’ Temperature
- 4.19 Auxiliary VDC inputs (2064)
- 5.0 Windows Interface
- 5.1 Distribution Files
- 5.2 Using the SMU2060 Driver With C++ or Similar Software
- 5.3 Visual Basic DMM Panel Application
- 5.4 Windows DLL Default Modes and Parameters
- 5.5 Using the SMU2060 DLL with LabWindows/CVI
- 5.6 Windows Command Language
- DMMArmAnalogTrigger
- DMMArmTrigger
- DMMBurstBuffRead
- DMMBurstRead
- DMMCalibrate
- DMMCleanRelay
- DMMClearMinMax
- DMMCloseUSB
- DMMDelayedTrigger
- DMMDisableTrimDAC
- DMMDisarmTrigger
- DMMDutyCycleStr
- DMMErrString
- DMMFrequencyStr
- DMMGetACCapsR
- DMMGetAperture
- DMMGetAverageVAC
- DMMGetBufferSize
- DMMGetBusInfo
- DMMGetCalDate
- DMMGetdB
- DMMGetdBStr
- DMMGetCJTemp
- DMMGetCounterRange
- DMMGetDeviation
- DMMGetDeviatStr
- DMMGetDevLocation
- DMMGetDiffMnMxStr
- DMMGetFuncRange
- DMMGetFunction
- DMMGetGrdVer
- DMMGetHwVer
- DMMGetHwOption
- DMMGetID
- DMMGetLowFreqVRMS
- DMMGetManDate
- DMMGetMax
- DMMGetMaxStr
- DMMGetMin
- DMMGetMinStr
- DMMGetNumDevices
- DMMGetRange
- DMMGetReadInterval
- DMMGetSourceFreq
- DMMGetStoredReading
- DMMGetSourceMode
- DMMGetTCType
- DMMGetTrigger
- DMMGetTriggerInfo
- DMMGetType
- DMMGetVer
- DMMInit
- DMMIsAutoRange
- DMMIsInitialized
- DMMIsRelative
- DMMLongTrigger
- DMMLongTrigRead
- DMMOpenCalACCaps
- DMMOpenTerminalCal
- DMMOpenUSB
- DMMOutputSync
- DMMPeriodStr
- DMMQuickInit
- DMMRead
- DMMReadBuffer
- DMMReadBufferStr
- DMMReadCJTemp
- DMMReadCrestFactor
- DMMReadDutyCycle
- DMMReadSR
- DMMReadFrequency
- DMMReadHiLoSense
- DMMReadHiSense
- DMMReadInductorQ
- DMMReadInductorR
- DMMReadLoSense
- DMMReadMeasurement
- DMMReadMedian
- DMMReadNorm
- DMMReadNsamples
- DMMReadPeakToPeak
- DMMReadPeriod
- DMMReadStr
- DMMReadTestV
- DMMReadTotalizer
- DMMReadWidth
- DMMReady
- DMMSetACCapsDelay
- DMMSetACCapsLevel
- DMMSetACVSource
- DMMSetAperture
- DMMSetAutoRange
- DMMSetBuffTrigRead
- DMMSetCapsAveSamp
- DMMSetCJTemp
- DMMSetCompThreshold
- DMMSetCounterRng
- DMMSetDCISource
- DMMSetDCVSource
- DMMSetFastRMS
- DMMSetFuncRange
- DMMSetFunction
- DMMSetInductFreq
- DMMSetOffsetOhms
- DMMSetPLC
- DMMSetPulseGen
- DMMSetRange
- DMMSetReadInterval
- DMMSetReference
- DMMSetRelative
- DMMSetRTD
- DMMSetSensorParams
- DMMSetSourceMode
- DMMSetSourceRes
- DMMSetSync
- DMMSetTCType
- DMMSetTempUnits
- DMMSetTrigPolarity
- DMMSetTrigRead
- DMMSetTrimDAC
- DMMStartTotalizer
- DMMStopTotalizer
- DMMTerminate
- DMMTrigger
- DMMTriggerBurst
- DMMUnlockCounter
- DMMWaitForTrigger
- DMMWidthStr
- 5.7 Calibration and Service Commands
- 5.8 Service Commands
- 5.9 Error Codes
- 5.10 Warning Codes
- 5.11 Parameter List
- 6.0 Maintenance
- 7.0 Warranty and Service
- 8.0 Accessories
3 Signametrics
TABLE OF CONTENTS
1.0 INTRODUCTION .................................................................................................................................................8
1.1 SAFETY CONSIDERATIONS..........................................................................................................................8
1.2 MINIMUM REQUIREMENTS .........................................................................................................................8
1.3 FEATURE SET .............................................................................................................................................8
2.0 SPECIFICATIONS .............................................................................................................................................10
2.1 DC VOLTAGE MEASUREMENT .................................................................................................................10
2.2 DC CURRENT MEASUREMENT..................................................................................................................10
2.3 RESISTANCE MEASUREMENTS..................................................................................................................11
2.3.1 2-wire.....................................................................................................................................11
2.3.2 4-wire.....................................................................................................................................11
2.3.3 6-wire Guarded Resistance Measurement (SMU2064) .........................................................11
2.3.4 Extended Resistance Measurements (SMU2064)...................................................................12
2.3.5 Offset Ohms Measurements (SMU2064)................................................................................12
2.4 AC VOLTAGE MEASUREMENTS................................................................................................................12
2.4.1 AC Voltage True RMS Measurement.....................................................................................12
2.4.2 AC Peak-to-Peak Measurement (SMU2064).........................................................................14
2.4.3 AC Crest Factor Measurement (SMU2064) ..........................................................................14
2.4.4 AC Median Value Measurement (SMU2064) ........................................................................15
2.4.5 Average AC Voltage Measurement (2064) ............................................................................15
2.4.6 Low frequency RMS Voltage Measurement (2064) ...............................................................15
2.5 AC CURRENT MEASUREMENT, TRUE RMS..............................................................................................15
2.6 LEAKAGE MEASUREMENT (SMU2064)....................................................................................................16
2.7 RTD TEMPERATURE MEASUREMENT .......................................................................................................16
2.8 THERMOCOUPLE TEMPERATURE MEASUREMENT.....................................................................................17
2.9 ADDITIONAL COMPONENT MEASUREMENT CAPABILITY ..........................................................................17
2.9.1 Diode Characterization .........................................................................................................17
2.9.2 Capacitance ...........................................................................................................................17
2.9.3 Capacitance, In-Circuit Method (SMU2064) ........................................................................18
2.9.4 Inductance Measurement (SMU2064) ...................................................................................18
2.10 TIME MEASUREMENTS ...........................................................................................................................19
2.10.1 Threshold DAC (SMU2064) ................................................................................................19
2.10.2 Frequency and Period Measurements .................................................................................19
2.10.3 Duty Cycle Measurement.....................................................................................................19
2.10.4 Pulse Width..........................................................................................................................19
2.10.5 Totalizer (SMU2064) ...........................................................................................................19
2.11 TRIGGER FUNCTIONS..............................................................................................................................20
2.11.1 External Hardware Trigger (at DIN-7 connector) ..............................................................20
2.11.2 Analog Threshold Trigger....................................................................................................20
2.11.3 Long Trigger (SMU2064 with Option ‘R’) ..........................................................................20
2.11.4 Delayed Hardware Trigger..................................................................................................20
2.12 MEASUREMENT TIMES ...........................................................................................................................20
2.12.1 Measurement Apertures and Read Interval .........................................................................20
2.12.2 Range and Function Transition Times.................................................................................22
2.13 SOURCE FUNCTIONS (2064) ...................................................................................................................22
2.13.1 DC Voltage, Measure DC Voltage.......................................................................................23
2.13.2 Source DC Voltage, Measure DC Current ..........................................................................23
2.13.3 Source AC Voltage, Measure AC Voltage ...........................................................................23
2.13.4 Source DC Current Measure DC Voltage ...........................................................................24
2.13.5 Pulse Generator...................................................................................................................24
2.14 ACCURACY NOTES .................................................................................................................................24
2.15 OTHER SPECIFICATIONS .........................................................................................................................25
3.0 GETTING STARTED.........................................................................................................................................27
3.1 SETTING UP THE DMM.............................................................................................................................27